Implantation of leadless pacemaker through neo-orifice after tricuspid valve edge-to-edge repair.

Europace

Department of Internal Medicine III, Cardiology and Angiology, Hospital of Medical University of Innsbruck, Anichstraße 35, A-6020 Innsbruck, Austria.

Published: June 2020

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euaa047DOI Listing

Publication Analysis

Top Keywords

implantation leadless
4
leadless pacemaker
4
pacemaker neo-orifice
4
neo-orifice tricuspid
4
tricuspid valve
4
valve edge-to-edge
4
edge-to-edge repair
4
implantation
1
pacemaker
1
neo-orifice
1

Similar Publications

: Leadless pacemakers offer a safe and effective alternative pacing strategy. However, limited data are available for patients with end stage renal disease (ESRD), a population of significant relevance. Using the Nationwide Readmission Database, we extracted data from all adult patients with ESRD who underwent traditional transvenous or leadless pacemaker implantation between 2016 and 2021.

View Article and Find Full Text PDF

We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully.

View Article and Find Full Text PDF

Background: The growing use of leadless pacemaker (LP) technology requires safe and effective solutions for retrieving and removing these devices over the long term.

Objectives: This study sought to evaluate retrieval and removal of an active helix-fixation LP studied in worldwide regulatory clinical trials.

Methods: Subjects enrolled in the LEADLESS II phase 1 investigational device exemption, LEADLESS Observational, or LEADLESS Japan trials with an attempted LP retrieval at least 6 weeks postimplantation were included.

View Article and Find Full Text PDF

A leadless pacemaker (LP) is a modern alternative to a transvenous pacemaker, allowing certain complications to be avoided; however, some cannot be eliminated. To highlight the essential role of advanced speckle-tracking echocardiography (STE) in diagnosing pacing-induced cardiomyopathy (PICM) caused by an LP. A 79-year-old male, after LP implantation a year earlier, was admitted due to heart failure (HF).

View Article and Find Full Text PDF

A 21-year-old man, known case of the repaired congenital heart disease, developed complete atrioventricular block (AVB) one week after simultaneous bioprosthetic pulmonary and tricuspid valve replacement and atrial septal defect repair. Considering the persistence of the AVB, it was decided to implant a permanent pacemaker. After considering all available options and the issues related to the patient, it was decided to implant a leadless pacemaker (LLP).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!