Background: The clinical impact of percutaneous coronary intervention (PCI) and implantation of overlapping stents (OS) using platforms with the same versus different pharmacological characteristics is unknown. Our objective was to compare the outcomes of PCI with OS according to their pharmacological characteristics.
Methods: In this observational single-center registry, we included all PCI performed from April 2014 to December 2018 in which overlapping drug-eluting stents were implanted. Two groups were created according to whether the stents release the same drug [homogeneous: (HO)] or different [heterogeneous: (HE)]. The primary endpoint was the need for target lesion revascularization (TLR). Clinical assessment was performed after the procedure, bianually and at the end of follow-up (June 2019).
Results: 381 lesions with OS (HO: 209; HE: 172) were included (75.1% male, 66.7 ± 11.6 years). Clinical presentation was stable coronary artery disease in 49.9%. Syntax score was 23.7 ± 13.3. The number of OS implanted was 2.2 ± 0.5 and the total stent length was 59.5 ± 20.1 mm (HE: 61.5 ± 21.6 vs. HO: 57.8 ± 18.8 mm; p < 0.01). After a median follow-up of 21 months, the HE group showed a lower TLR rate than the HO group (HE:2.3% vs HO:7.2%; p = 0.03). The rates of cardiac death (p = 0.44), myocardial infarction (p = 0.36) and stent thrombosis (p = 0.85) were similar between groups. In the multivariate analysis, the OS with homogeneous-drug devices was an independent predictor of a higher rate of TLR.
Conclusions: PCI using OS with homogeneous pharmacological characteristics was associated with a higher rate of TLR in comparison with the implantation of OS with heterogeneous pharmacological characteristics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.carrev.2020.04.025 | DOI Listing |
The guide extension-facilitated ostial stenting (GEST) technique uses a guide extension catheter (GEC) to improve stent delivery during primary coronary angioplasty (PCI). GECs are used for stent delivery into the coronary arteries of patients with difficult anatomy due to tortuosity, calcification, or chronic total occlusion (CTO) vessels. Stent and balloon placement has become challenging in patients with increasing lesion complexity due to tortuosity, vessel morphology, length of the lesion, and respiratory movements.
View Article and Find Full Text PDFBMC Neurol
December 2024
Department of Neurological Surgery, The First College of Clinical Medical Science, China Three Gorges University, Yichang Central People's Hospital, 183 Yiling Avenue, Yichang City, Wujiagang District, China.
Objective: The study aims to identify characteristics that impact the postoperative prognosis and recurrence of intracranial dissecting aneurysms (IDA) patients treated using multi-stent overlapping techniques.
Methods: Clinical data from 69 IDA patients treated with multistate-assisted spring coil embolization at the hospital between January 2017 and October 2023 were retrospectively reviewed, including clinical and imaging data gathered at admission and discharge. The prognosis was determined based on mRS grade at discharge, and the patients were divided into excellent prognosis (mRS 0-2 points) and poor prognosis (mRS 3-6 points).
Diagn Interv Radiol
December 2024
Ege University Faculty of Medicine, Department of Interventional Radiology, İzmir, Türkiye.
Purpose: This study aims to investigate the indications and therapeutic efficacy of flow-diverting stents (FDSs) in the management of extracranial carotid artery aneurysms (ECAAs) and dissections.
Methods: A retrospective analysis was conducted on 18 patients treated for ECAAs with an FDS between 2010 and 2024. Patient demographics, aneurysm characteristics, procedural details, and clinical and radiologic follow-up outcomes were extracted from medical records.
Cureus
November 2024
Neurosurgery, Kokura Memorial Hospital, Kitakyushu, JPN.
Carotid artery stenosis is a significant cause of ischemic stroke, often necessitating interventions like carotid artery stenting (CAS) to restore adequate blood flow. However, complications like intraprocedural arterial dissection can arise during the procedure. This report presents a case of intraprocedural arterial dissection during CAS using a CASPER Rx stent.
View Article and Find Full Text PDFEur Radiol
December 2024
Thoracic Surgery Unit, Fondazione IRCCS Istituto Nazionale Tumori, Milan, Italy.
Objectives: To assess the consistency of automated measurements of coronary artery calcification (CAC) burden and emphysema extent on computed tomography (CT) images acquired with different radiation dose protocols in a lung cancer screening (LCS) population.
Materials And Methods: The patient cohort comprised 361 consecutive screenees who underwent a low-dose CT (LDCT) scan and an ultra-low-dose CT (ULDCT) scan at an incident screening round. Exclusion criteria for CAC measurements were software failure and previous history of CVD, including coronary stenting, whereas for emphysema assessment, software failure only.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!