Thrombin generation is a complex and finely regulated pathway that provokes dynamical changes of thrombin concentration in blood when a vascular injury occurs. In order to characterize the initiation phase of such process, when thrombin concentration is in the nmol/L range, a label-free optical aptasensor is proposed here. This aptasensor combines a 1D photonic crystal structure consisting of a silicon corrugated waveguide with thrombin binding aptamers on its surface as bioreceptors. As a result, this aptasensor has been demonstrated to specifically detect thrombin concentrations ranging from 270 pmol/L to 27 nmol/L with an estimated detection limit of 33.5 pmol/L and a response time of ~2 min. Furthermore, it has also been demonstrated that this aptasensor is able to continuously respond to consecutive increasing concentrations of thrombin and to detect binding events as they occur. All these features make this aptasensor a good candidate to continuously study how thrombin concentration progressively increases during the initiation phase of the coagulation cascade.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7281654 | PMC |
http://dx.doi.org/10.3390/mi11050464 | DOI Listing |
Thromb Haemost
January 2025
Department of Medical Physiology, Hamamatsu University School of Medicine, Hamamatsu, Japan.
Background: Fibrinolysis is spatiotemporally well-regulated and greatly influenced by activated platelets and coagulation activity. Our previous real-time imaging analyses revealed that clotting commences on activated platelet surfaces, resulting in uneven-density fibrin structures, and that fibrinolysis initiates in dense fibrin regions and extends to the periphery. Despite the widespread clinical use of direct oral anticoagulants (DOACs), their impact on thrombin-dependent activation of thrombin-activatable fibrinolysis inhibitor (TAFI) and fibrinolysis remains unclear.
View Article and Find Full Text PDFCurr Eye Res
January 2025
Centre for Ophthalmology, Eberhard-Karls University, Tübingen, Germany.
Purpose: This study explores the potential interaction of brolucizumab with platelets and its effects on platelet activation and reactivity, crucial in retinal vasculitis and retinal vascular occlusion. Safety concerns remain of interest, although brolucizumab showed superior retinal efficacy and reduced injection frequency compared to other licensed anti-VEGF agents.
Methods: Resting and activated platelets of healthy volunteers were pretreated with brolucizumab at the following concentrations 0.
ACS Omega
December 2024
Department of Biochemistry, Federal University of São Paulo, São Paulo, SP 04044-020, Brazil.
Br J Anaesth
January 2025
Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria; Department of Anesthesiology and Intensive Care Medicine AUVA Trauma Center Salzburg, Academic Teaching Hospital of the Paracelsus Medical University, Salzburg, Austria.
Background: Bleeding guidelines currently recommend use of viscoelastic testing (VET) to direct haemostatic resuscitation in severe haemorrhage. However, VET-derived parameters of clot initiation, such as clotting time (CT) and activated clotting time (ACT), might not adequately reflect a clinically relevant interaction of procoagulant and anticoagulant activity, as revealed by thrombin generation assays. The aim of this study was to evaluate the ability of CT and ACT to indicate thrombin generation activity.
View Article and Find Full Text PDFSens Actuators B Chem
January 2025
Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Sensitive detection of disease-specific biomarkers with high accuracy is crucial for early diagnosis, therapeutic monitoring, and understanding underlying pathological mechanisms. Traditional methods, such as immunohistochemistry and enzyme-linked immunosorbent assays (ELISA), face limitations due to the complex and expensive production of antibodies. In this context, aptamers, short oligonucleotides with advantages like easy synthesis, low cost, high specificity, and stability, have emerged as promising alternatives for biomolecular sensing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!