Late left atrial appendage closure device displacement and massive thrombus formation: a case report.

Eur Heart J Case Rep

Department of Internal Medicine I - Cardiology, Brandenburg Medical Faculty, Hochstr. 29, 14770 Brandenburg/Havel, Germany.

Published: April 2020

Background: Left atrial appendage (LAA) closure with the WATCHMAN device is an alternative to anticoagulation therapy for the prevention of stroke in selected patients with atrial fibrillation (AF). Infrequently, left atrial (LA) device-related thrombus formation occurs and it is poorly understood. Thrombus formation due to incomplete covering of the LAA is even rarer and may occur within the first few months after device implantation.

Case Summary: Here, we present a case of a 68-year-old male patient with permanent AF, drug- and hepatitis induced liver cirrhosis (CILD Score B), and prior aortic valve replacement. The patient had a history of percutaneous LAA closure using a WATCHMAN device. He developed massive peri-device leak and thrombus arising from the space between the device and appendage cleft 2 years after implantation. Because of the high bleeding risk with a HAS-BLED score of 5 points, surgery was chosen as the therapy of choice instead of long-term anticoagulation. The patient was discharged in good clinical condition and has been scheduled for a yearly follow-up.

Discussion: This case emphasizes the importance of choosing appropriately sized LAA occluder devices and planning for regular post-interventional follow-ups to minimize the risk of per-device leaks and thrombi.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180543PMC
http://dx.doi.org/10.1093/ehjcr/ytaa014DOI Listing

Publication Analysis

Top Keywords

left atrial
12
thrombus formation
12
atrial appendage
8
laa closure
8
closure watchman
8
watchman device
8
device
5
late left
4
atrial
4
appendage closure
4

Similar Publications

We present a case of a 72-year-old female patient with dyspnea and lipothymia. Echocardiography demonstrates an intracavitary cystic mass that fills almost all left atria causing supravalvular obstruction. The magnetic resonance image revealed a 53 × 47 × 48 mm heterogeneous mass with regular edges, tissue characterization suggested myxoma.

View Article and Find Full Text PDF

Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.

Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.

View Article and Find Full Text PDF

Introduction The study aimed to retrospectively evaluate the early patient outcome and left ventricular function after mitral valve replacement with a tilting disc valve and total preservation. Patients and methods This retrospective observational study includes patients who underwent mitral valve replacement using a tilting disc valve with total preservation of mitral valvular and subvalvular apparatus from July 2021 to August 2022 at a single center. Results The data were reviewed retrospectively for age, sex, comorbidities, operating time, aortic cross-clamp time, cardiopulmonary bypass time, preoperative and postoperative left ventricular ejection fraction, mean gradient across the mitral valve, left ventricular diameter, left atrial size, atrial fibrillation, complications, mortality, and early patient outcome.

View Article and Find Full Text PDF

The aim of this study was to evaluate the association between spontaneous echocardiographic contrast (SEC) and left atrial (LA) parameters such as size, volume, and function in cats with hypertrophic cardiomyopathy (HCM). Cats were assigned into following groups: clinically healthy cats (n=8), HCM without SEC (n=12), and HCM with SEC (n=8). Left atrial shortening fraction (LAFS%) and left atrial fractional area change (LAFAC) had statistical significance between groups.

View Article and Find Full Text PDF

Cardiovascular problems in rabbits in reference to hypothyroidism - a four-year retrospective study.

Pol J Vet Sci

December 2024

Department of Epizootiology and the Clinic of Infectious Diseases, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Głęboka 30, 20-612 Lublin, Poland.

The effects of T4 are mainly manifested by positive ino- and chronotropism. The syndrome accompanying hypothyroidism in rabbits (impaired myocardial contractility and reduced ejection capacity) is caused by a deficiency of thyroid hormones - especially T4. The study group consisted of a total of 41 animals: 15 males and 26 females, ranging in age from 2 months to 8 years, with echocardiogram showing reduced fractional shortening (<30%), with normal results of heamatological and biochemical tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!