Hepatectomy using a novel cart-based indocyanine green fluorescence imaging system.

Surg Today

Department of Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, 663-8501, Japan.

Published: October 2020

Indocyanine green (ICG) fluorescence has been used effectively in imaging for locating hepatic tumors and evaluating hepatic segmentation. We report our initial experience of performing hepatic resection using the novel cart-based ICG fluorescence device LIGHTVISION. This device has several promising features, including the fact that there is no need to switch off the room light, it has hands-free operability, and it can be located away from the workspace to facilitate a good field of vision. We used the LIGHTVISION for 15 patients and detected 59 nodules (86.8%) in a total of 68 tumors in the resected specimens during surgery. The LIGHTVISION was used to identify the hepatic segments in ten patients, and the boundaries of the segment were clearly visualized on the liver surface on fluorescent images in all patients. All tumors were resected with surgical margins. Thus, the LIGHTVISION appears to be very useful for navigation in liver surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00595-020-02005-7DOI Listing

Publication Analysis

Top Keywords

novel cart-based
8
indocyanine green
8
icg fluorescence
8
tumors resected
8
hepatectomy novel
4
cart-based indocyanine
4
green fluorescence
4
fluorescence imaging
4
imaging system
4
system indocyanine
4

Similar Publications

Article Synopsis
  • About 70% of bladder cancer cases are non-muscle invasive (NMIBC) and inflammation, influenced by factors like smoking, affects treatment outcomes with BCG therapy.
  • A study analyzed data from 1,313 NMIBC patients to examine how smoking and systemic inflammation impact the effectiveness of BCG using a machine-learning algorithm.
  • The results indicated that both smoking status and specific inflammatory markers can significantly predict the risk of disease progression, highlighting the need for tailored treatment strategies and further research to confirm the findings.
View Article and Find Full Text PDF

Aims: We sought to evaluate the reliability and diagnostic accuracy of a novel handheld ultrasound device (HUD) with artificial intelligence (AI) assisted algorithm to automatically calculate ejection fraction (autoEF) in a real-world patient population.

Methods And Results: We studied 100 consecutive patients (57 ± 15 years old, 61% male), including 38 with abnormal left ventricular (LV) function [LV ejection fraction (LVEF) < 50%]. The autoEF results acquired using the HUD were independently compared with manually traced biplane Simpson's rule measurements on cart-based systems to assess method agreement using intra-class correlation coefficient (ICC), linear regression analysis, and Bland-Altman analysis.

View Article and Find Full Text PDF

Asynchronous training for ultrasound-guided peripheral IV placement among critical care nurses.

J Vasc Access

May 2024

Department of Critical Care Medicine, Veterans Affairs of Pittsburgh Health Care Systems, Pittsburgh, PA, USA.

Objective: Teaching ultrasound (US) guidance for placement of peripheral intravenous (PIV) catheters requires significant time for synchronous didactic and hands-on training. The investigators assessed the feasibility of an asynchronous model for critical care nurses to learn the novel skill of US-guided PIV placement. Secondary outcomes included the percentage of successful attempts and number of sticks per attempt for anatomy versus US-guided approaches.

View Article and Find Full Text PDF

A Novel Handheld Echocardiography Device with Continuous-Wave Doppler Capability: Implications for the Evaluation of Aortic Stenosis Severity.

J Am Soc Echocardiogr

December 2022

Imperial College London, National Heart & Lung Institute, The Hammersmith Hospital, London, United Kingdom; First Cardiology Department, Medical School, University of Athens, Hippokration Hospital, Athens, Greece.

Background: The aim of this study was to evaluate the ability of a novel handheld echocardiography (HHE) device with continuous-wave Doppler (CWD) capability to measure aortic valve peak jet velocity (Vmax) and facilitate aortic stenosis (AS) severity grading.

Methods: One hundred twenty-one consecutive patients with known or suspected AS were prospectively included. All patients were scanned with the HHE device and a high-end echocardiography system (the reference standard) to obtain CWD signal across the aortic valve.

View Article and Find Full Text PDF

Dyspnoea self-management is often suboptimal for patients with COPD. Many patients with COPD experience chronic dyspnoea as distressing and disabling, especially during physical activities. Breathing therapy is a behavioural intervention that targets reducing the distress and impact of dyspnoea on exertion in daily living.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!