A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On the Thermal Performance of a Fractal Microchannel Subjected to Water and Kerosene Carbon Nanotube Nanofluid. | LitMetric

Using single layer microchannels accompanied by nanofluids is one of the most practical solutions in thermal management of high power density devices. The main challenge in cooling systems of electronic devices is to provide a uniform temperature distribution. In the present study, fluid flow and heat transfer in a fractal microchannel heatsink have been simulated employing the computational fluid dynamics (CFD) method. The fractal microchannel is used to achieve uniform temperature distribution. Thermal performance of single-walled carbon nanotubes (SWCNT) and multi-walled carbon nanotubes (MWCNT) dispersed in the two base fluids of water and kerosene in a fractal microchannel at Reynolds (Re) numbers of 1500 to 3000 are investigated. It should be noted that the nanofluids have been simulated by the two-phase mixture model. The results indicated that the use of fractals silicon microchannel leads to having a uniform temperature distribution. Based on the results, at maximum Re number when the working fluid is water, Nu number and pumping power are 20.9 and 0.033 W whereas, in kerosene flow at the same condition, Nu number and pumping power are 6 and 0.054 W, respectively. According to the obtained results, using the SWCNT nanoparticle compared with the MWCNT nanoparticle leads to a significant enhancement in the Nusselt (Nu) number. This difference is more pronounced by increasing the Re number and nanoparticle volume fraction. In addition, the results indicated that at the same Re number and nanoparticle volume fraction, the performance evaluation criterion of the water-based nanofluid is 4 times higher than that of the kerosene-based nanofluid. So the use of the water as the working fluid with the SWCNT nanoparticle for cooling in the fractal silicon microchannel is recommended.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7190658PMC
http://dx.doi.org/10.1038/s41598-020-64142-wDOI Listing

Publication Analysis

Top Keywords

fractal microchannel
16
uniform temperature
12
temperature distribution
12
thermal performance
8
water kerosene
8
carbon nanotubes
8
silicon microchannel
8
working fluid
8
number pumping
8
pumping power
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!