Locking Plate Fixation for Canine Acetabular Fractures.

Vet Comp Orthop Traumatol

Lumbry Park Veterinary Specialists, Alton, United Kingdom.

Published: July 2020

Objective:  The aim of this study was to document application of locking plates for stabilization of acetabular fractures along with complications and clinical outcomes. We hypothesized that complications and clinical outcomes would be comparable to historical reports using non-locking plate and screw constructs.

Study Design:  Medical records of dogs presented with acetabular fractures at a single referral centre between 2010 and 2018 were reviewed. Cases surgically managed by open reduction and internal fixation, involving placement of at least one locking plate and screws, were included. Signalment, fracture classification, type of implant used, additional methods of stabilization, along with complications and neurological deficits, were collected. Long-term follow-up was based on Liverpool Osteoarthritis in Dogs questionnaire.

Results:  Eighteen acetabula were repaired in 17 dogs. Locking implants were VetLOX (4/18), string-of-pearls (7/18) and locking compression plates (7/18). Locking plates and screws were used as the sole method of fixation in 10/18 acetabula, and as adjunctive fixation with other implants in 8/18 acetabula. Two minor complications and one catastrophic complication were reported. Sixteen of seventeen dogs returned to function with radiographic documentation of fracture healing. Complication rate was comparable to historic reports using non-locking implants. Long-term outcomes assessed by Liverpool Osteoarthritis in Dogs questionnaire were positive in most cases.

Conclusion:  Locking plates are a viable means of stabilizing acetabular fractures in dogs and can provide positive clinical outcomes. Surprisingly, problems including inaccurate fracture reduction and implant loosening were not fully avoided by use of locking implants but incidence was low.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1708522DOI Listing

Publication Analysis

Top Keywords

acetabular fractures
16
clinical outcomes
12
locking plate
8
locking plates
8
complications clinical
8
reports non-locking
8
liverpool osteoarthritis
8
osteoarthritis dogs
8
locking implants
8
7/18 locking
8

Similar Publications

Background: Pelvic fractures often result in traumatic and intraoperative blood loss. Cell salvage (CS) is a tool where autologous blood lost during surgery is collected and recycled with anticoagulation, centrifugation to separate red blood cells, and washing to be reinfused back to the patient. The purpose of this study was to investigate our experience with CS in pelvic and acetabular surgery and its relationship to perioperative transfusion requirements.

View Article and Find Full Text PDF

Introduction: The occurrence of non-traumatic bilateral femoral neck fractures is exceedingly rare, and their manifestation subsequent to an epileptic attack is an uncommon entity with very few cases reported globally.

Case Report: We present the positive outcome of a 68-year-old man who underwent staged bilateral constrained total hip arthroplasty following a fracture resulting from a generalized seizure. This unconventional decision was justified based on several factors, including fracture pattern, bone quality, seizure history, and advanced tribology.

View Article and Find Full Text PDF

Acetabular fractures are rare fractures of the pelvis which usually result from trauma. Whilst data are reported on sexual and genitourinary function in those with pelvic fractures, less is known about those with isolated acetabulum fractures. This systematic review aimed to determine, first, the frequency of sexual and genitourinary dysfunction following isolated acetabulum fractures and, second, the nature of these complications.

View Article and Find Full Text PDF

Objectives: The 22-modifier in the Current Procedural Terminology (CPT) system indicates increased surgical procedure complexity, aiming to secure greater reimbursement for surgeons. This study investigated the 22-modifier on reimbursement amounts after acetabular fracture fixation.

Methods: Design: Retrospective cohort study.

View Article and Find Full Text PDF

Objectives: To report the frequency of patients with pre- and post-reduction computed tomography (CT) scans associated with acetabular fracture-dislocations and the change of associated intra-articular fragments occurring with joint reduction.

Methods: Design: Retrospective case series.

Setting: Regional Level 1 trauma center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!