Effect of an implant-retained complete overdenture on the hearing ability of edentulous patients: A clinical pilot study.

J Prosthet Dent

Former-Professor and Head, Department of Prosthodontics, Faculty of Dental Sciences, SRIHER, Porur, Tamilnadu, India.

Published: April 2021

Statement Of Problem: Edentulism has been associated with sensoneurinal hearing reduction, but whether hearing is improved by the provision of an implant-retained overdenture is unclear.

Purpose: The purpose of this pilot clinical study was to provide completely edentulous participants with implant-retained complete overdentures and to evaluate the effect on their hearing ability by pure tone audiometry (PTA).

Material And Methods: Fifteen completely edentulous first-time denture wearers were enrolled, and their hearing was evaluated with PTA for air conduction and bone conduction at 6 time intervals: before denture insertion (R1), after denture insertion (R2), 1 month after denture insertion (R3), on the day of suture removal after implant surgery (R4), 3 months later, at the time of loading (R5), and 1 month after implant loading (R6). The Friedman test was performed to find significant differences in the measurements from the completely edentulous state to rehabilitation with a complete denture and an implant-retained complete overdenture. The post hoc Tukey test was used for multiple comparisons (α=.05).

Results: Significant differences were found between R1 and R6, between R2 and R6, between R3 and R6, and between R4 and R6 in PTA in multiple comparisons (P<.05). The post hoc test revealed significant difference in the R1and R6 and R3 and R6 pairs (P<.05) at 500 Hz, 1 kHz, and 8 kHz, whereas only between R1 and R6 (P<.05) at 2 kHz for the air conduction test. In the bone conduction test, a significant difference was observed between the R1 and R6 and the R3 and R6 pairs (P<.05) at 500 Hz and 4 kHz, but only between R3 and R6 (P<.05) at 1 kHz and 2 kHz.

Conclusions: The study showed that the placement of dental implants improved hearing acuity via the acoustic pathway through air and bone conduction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2020.02.015DOI Listing

Publication Analysis

Top Keywords

implant-retained complete
12
completely edentulous
12
denture insertion
12
complete overdenture
8
hearing ability
8
multiple comparisons
8
hearing
5
denture
5
implant-retained
4
overdenture hearing
4

Similar Publications

Purpose: In this randomized clinical trial, we examined the incorporation of nanogold particles into polymethyl methacrylate denture bases and compared these modified bases with conventional ones in mandibular implant-retained overdentures, focusing on microbiological growth and adhesion characteristics.

Methods: In this study, twenty-two male patients who were completely edentulous participated in a rehabilitation program involving mandibular overdentures retained by two dental implants placed in the canine area. The subjects were categorized into two equal groups, each comprising eleven patients.

View Article and Find Full Text PDF

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

Objective: To compare the effectiveness of prosthetic rehabilitation of edentulous patients using conventional complete dentures (CD), single median dental implant retained over dentures (SIMOD) with over dentures retained by two dental implants (TIMOD).

Methods: Thirty completely edentulous patients (fifteen each arm) presented to the Faculty of Dental Sciences, University of Peradeniya were randomly selected for the SIMOD or TIMOD groups. Patients were initially provided with CD.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on rehabilitating maxillary single denture cases using two types of implant-retained attachments: telescopic and ball-and-socket, to see which provided better patient satisfaction.
  • It involved 18 completely edentulous patients aged 45-60, where each received a maxillary single denture with different attachment systems, and their satisfaction was assessed immediately after and three months later.
  • Results indicated that patients with telescopic attachments reported greater improvements in comfort, chewing, and overall satisfaction, while those with ball-and-socket attachments only noted better appearance, highlighting the advantages of telescopic systems.
View Article and Find Full Text PDF

Minimally invasive approaches for implant-supported overdentures in the atrophied mandible.

Gerodontology

November 2024

Department of Prosthetic Dentistry, University School of Dental Medicine, Martin-Luther-University, Halle-Wittenberg, Halle, Germany.

Objectives: The study compares three minimally invasive approaches for the retention of implant supported mandibular complete dentures, particularly focusing on patient satisfaction.

Background: The McGill Consensus Statement recommends restoration of the edentulous mandible with an overdenture retained on two implants. Alternatively, less invasive treatment concepts with shorter treatment times have been developed for critical cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!