Introduction: Central venous stenosis can be the main obstacle to the creation of an autologous vascular access in the upper limbs. The Hemodialysis Reliable Outflow graft was developed to provide an upper limb vascular access option to such patients, avoiding alternative, less advantageous options, such as lower limb vascular accesses or central venous catheters. Its advantages include catheter avoidance and, in case of lower limbs accesses, reduction of the ischemic risk and iliac vein thrombosis, potentially compromising a future kidney transplant.
Patients And Methods: Revision of the clinical files of the four patients who were placed a Hemodialysis Reliable Outflow device in our Center, including demographic variables, implantation technique characteristics, surgical complications, episodes of infection and thrombosis of the access, and need to place a transitory central venous catheter to undergo hemodialysis treatment.
Results: Four Hemodialysis Reliable Outflow grafts were placed, which resulted in a significant improvement in the dialysis efficacy in all patients, with a median raise in the Kt/V of 36.7%. Two cases needed thrombectomy, one of which was unsuccessful. The actual time of patency varies between 3 and 28 months.
Conclusion: Our experience with the Hemodialysis Reliable Outflow device showed that it was a safe option for patients with central venous stenosis and was associated with good clinical and analytic outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1129729820917255 | DOI Listing |
J Ren Care
March 2025
Department of Renal Medicine, Aarhus University Hospital, Aarhus, Denmark.
Background: Nursing sensitive indicators are a way of measuring aspects of patient care that are most affected by the actions of the nurse. Despite the existence of nursing sensitive indicators, these are largely not suitable to measure peritoneal dialysis nursing practice.
Objective: This project aimed to co-develop a set of peritoneal dialysis nursing-sensitive indicators.
Front Med (Lausanne)
January 2025
Department of General Medicine, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research (DMIHER), Wardha, India.
Background: Cardiac autonomic neuropathy (CAN) is a significant complication in chronic kidney disease (CKD), leading to increased morbidity and mortality. Early detection is essential for managing CKD patients effectively, especially those on hemodialysis. This study evaluated the prevalence CAN in CKD and diagnostic accuracy of Bellavere's Score in predicting CAN in CKD patients, including those undergoing hemodialysis.
View Article and Find Full Text PDFHealth Sci Rep
January 2025
Department of Cardiology Saiseikai Yokohama City Eastern Hospital Kanagawa Japan.
Background And Aims: When dealing with severely calcified lesions in endovascular therapy (EVT) for lower extremity artery disease (LEAD), navigating through severely calcified chronic total occlusion (CTO) using hard-tip guidewires can be challenging. To address this issue, we employed a novel highly intensive penetration (HIP) technique. This technique involves modifying the tail of a 0.
View Article and Find Full Text PDFJ Ren Nutr
January 2025
Department of Nursing and Physiotherapy, Universidad Cardenal Herrera-CEU, CEU Universities, C/ Santiago Ramón y Cajal s/n 46115, Alfara del Patriarca, Valencia, Spain.
Objective: The aim was to assess the intra and inter-rater reliability of the handheld dynamometry testing of lower limb muscles during hemodialysis.
Methods: This is a cross-sectional study including subjects undertaking hemodialysis for at least 3 months. Handheld dynamometer measurements of hip and ankle muscle strength (N) were registered on 4 different occasions, 2 trials by raters A and 2 by raters B, to evaluate the intra and inter-rater reliability.
J Clin Med
January 2025
Joyce and Irving Goldman Medical School, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel.
: Home rehabilitation improves patient satisfaction and reduces the need for specialist consultations. Hemodialysis is a costly post-ICU service that requires frequent monitoring. Previous studies have demonstrated the feasibility and accuracy of patients self-scanning their lungs with an ultrasound device within the hospital.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!