Background: A single, simplified approach for human immunodeficiency virus (HIV)-1/HIV-2 antibody confirmation/differentiation is needed for the HIV blood donation supplemental algorithm used in the United States. A clinical evaluation of the Geenius assay was performed-the same assay used for HIV diagnostic confirmation/differentiation in the United States since 2014.
Study Design And Methods: Well-characterized unlinked donation samples classified as HIV negative, false positive, or confirmed positive were included in the study: 200 antibody-nonreactive, 200 HIV-1 immunofluorescence assay (IFA) confirmed-positive, and 100 antibody-screen false-positive donations, equally divided between serum and plasma. Samples were retrieved from a repository, relabeled, and tested by an immunochromatographic test (Geenius HIV 1/2 Supplemental Assay, Bio-Rad). Comparator testing involved parallel US Food and Drug Administration (FDA)-licensed HIV-1 IFA or HIV-2 enzyme immunoassay (EIA) supplemental testing for any sample missing those results as part of routine testing (otherwise test-of-record results were used). Samples with discordant results were further tested with a rapid test (Multispot HIV-1/HIV-2 Rapid Test, Bio-Rad) to provide final sample interpretations. Testing volume reductions with the Geenius were estimated from screening performed by the American Red Cross from September 2016 to April 2019.
Results: Clinical results were 100% sensitivity and specificity with an indeterminate rate of 4.0% to 5.0%. From 2016 to 2019, sole use of the Geenius would reduce testing complexity for 5265 antibody repeat-reactive donations including 95.7% (5028) false positives, eliminating approximately 5000 unnecessary tests.
Conclusion: Geenius FDA licensure (August 26, 2019) adding the HIV-1/HIV-2 differentiation/confirmation donation supplemental claim will enable replacement of previously used FDA-licensed supplemental assays while maintaining comparable sensitivity, avoiding thousands of unnecessary HIV-1-IFA, western blot, and HIV-2-EIA tests.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/trf.15819 | DOI Listing |
J Infect Public Health
August 2024
Laboratorio de Epidemiología Molecular del VIH-1, Departamento de Microbiología, Hospital Universitario Ramón y Cajal-Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS) y RITIP-CoRISpe, 28034, Madrid, Spain; Centro de Investigación Biomédica en Red en Epidemiologia y Salud Pública (CIBERESP), 28029 Madrid, Spain. Electronic address:
Background: In Equatorial Guinea, only 54 % of people living with HIV know their HIV status. There are no confirmatory or molecular diagnostic techniques for early diagnosis or monitoring of infection in the country. Rapid diagnostic tests can induce false-positive diagnoses if used as a confirmatory technique.
View Article and Find Full Text PDFBMC Infect Dis
February 2024
Division of STD Prevention, Centers for Disease Control and Prevention, Atlanta, GA, 30329, USA.
Background: Sexually transmitted infections (STIs) such as syphilis and HIV remain to be a significant public health issue worldwide. Dual rapid point-of-care tests (POCTs) have shown promise for detecting antibodies to HIV and syphilis but have not been fully evaluated in the field. Our study supported the WHO ProSPeRo study on Sexually Transmitted Infection Point-of-Care Testing (STI POCT) by providing external quality assessment (EQA) for HIV and syphilis testing in reference laboratories and their associated clinical sites in seven countries.
View Article and Find Full Text PDFJ Acquir Immune Defic Syndr
April 2024
Division of Global HIV and TB, Center for Global Health, CDC, Atlanta, GA.
Background: HIV testing is a critical step to accessing antiretroviral therapy (ART) because early diagnosis can facilitate earlier initiation of ART. This study presents aggregated data of individuals who self-reported being HIV-positive but subsequently tested HIV-negative during nationally representative Population-Based HIV Impact Assessment surveys conducted in 11 countries from 2015 to 2018.
Method: Survey participants aged 15 years or older were interviewed by trained personnel using a standard questionnaire to determine HIV testing history and self-reported HIV status.
J Clin Microbiol
February 2024
Department of Pathology and Laboratory Medicine, UNC-Chapel Hill School of Medicine, Chapel Hill, North Carolina, USA.
HIV is an ongoing global epidemic with estimates of more than a million new infections occurring annually. To combat viral spread, continuous innovations in areas including testing and treatment are necessary. In the United States, the Centers for Disease Control and Prevention recommend that laboratories follow an HIV testing algorithm that first uses a US Food and Drug Administration approved immunoassay to detect antibodies to HIV-1 or HIV-2 as well as HIV-1 p24 antigen in serum or plasma samples.
View Article and Find Full Text PDFJ Clin Virol
February 2024
Faculty of Medicine, Tel-Aviv University, Israel; National HIV and Viral Hepatitis Reference Laboratory, Chaim Sheba Medical Center, Ministry of Health, Ramat Gan, Israel. Electronic address:
Background: Estimating HIV-1 recency of infection for incidence and local outbreaks detection usually involves specifically designed assays. Here, we established an approach to identify recent infections, estimate their rate, and assess potential risk factors.
Methods: Randomly selected HIV-1 positive samples (n = 382) collected in 2017-2021 were tested by Sedia and compared to the results of Geenius recency algorithm and the S/CO values of the HIV-1/2 Combo assay.