A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of a biopsy punch for end-to-side anastomosis in free-tissue transfer. | LitMetric

In end-to-side vessel-anastomoses, a side fenestration should be made by a slit incision or partial excision of the vessel wall. However, a slit incision might restrict blood flow across the anastomosis, and a partial vessel wall excision using micro-scissors may be time-consuming and result in irregular edges, which may weaken the vessel wall and cause flow disturbances. We used a biopsy punch for end-to-side anastomosis, and obtained satisfactory results. Between September 2015 and August 2017, 27 end-to-side anastomoses using punch biopsies were performed. Two vessel clamps were applied to the recipient vessel proximal and distal to the point planned for the side anastomosis. The flap side vessel size was measured, and an appropriately sized punch was selected. The clamped recipient vessel was supported by a wooden tongue depressor and the punch was applied to the vessel wall. An end-to-side anastomosis was performed in the usual manner, and immediate patency was tested with a refill test. The vessel patency rate was 96 percent. The mean arteriotomy or venotomy time was 65 s and entire anastomosis procedure time was 1065 s. Both the vessel preparation and the micro-anastomosis procedure times were shorter than those of the conventional procedure group with statistical significance. ( < .05) There was only one case of venous failure by deep vein thrombosis - and it was resolved with thrombectomy and re-anastomosis. Use of a biopsy punch in end-to-side anastomosis can offer a uniform circular edge and reduce operating time.

Download full-text PDF

Source
http://dx.doi.org/10.1080/2000656X.2020.1755297DOI Listing

Publication Analysis

Top Keywords

vessel wall
16
end-to-side anastomosis
12
vessel
10
biopsy punch
8
punch end-to-side
8
slit incision
8
recipient vessel
8
anastomosis
6
end-to-side
5
anastomosis free-tissue
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!