A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Pulmonary Gas Exchange During Kidney Transplantation: Second-Generation Laryngeal Mask Airway vs Endotracheal Tube. | LitMetric

Introduction: We evaluated whether second-generation laryngeal mask airway (LMA) could provide an adequate pulmonary gas exchange during prolonged abdominal surgery compared to endotracheal tube (ETT) using propensity score matching.

Methods: Of the 257 recipients who underwent living donor kidney transplantation (LDKT), the LMA group and ETT group were matched: 87 of 101 recipients who inserted second-generation LMA were matched with 87 of 156 recipients who inserted ETT. Arterial partial pressure of carbon dioxide (PaCO) and ratio of arterial partial pressure of oxygen to fractional inspired oxygen (PFR) and intraoperative ventilator parameters were compared between the 2 groups. In addition, we compared incidences of postoperative pulmonary and nonpulmonary complications including hoarseness, vocal cord palsy, nausea, vomiting, arrhythmia, and delirium between the 2 groups.

Results: Median anesthesia time was 357 minutes. PaCO and PFR were comparable between the 2 groups and did not show group and time interaction. Ventilator parameters during surgery were comparable, and incidences of both postoperative pulmonary and nonpulmonary complications were also comparable between the 2 groups.

Conclusion: Second-generation LMA could provide an adequate pulmonary gas exchange compared with ETT during LDKT. In terms of pulmonary gas exchange, second-generation LMA could be considered as a suitable alternative to ETT during prolonged abdominal surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.transproceed.2019.12.057DOI Listing

Publication Analysis

Top Keywords

pulmonary gas
16
gas exchange
16
second-generation lma
12
kidney transplantation
8
second-generation laryngeal
8
laryngeal mask
8
mask airway
8
endotracheal tube
8
lma provide
8
provide adequate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!