Introduction: Cephallomedullary nail fixation is currently the most popular treatment for pertrochanteric fractures. Despite continuous improvement in implant design, fixation failures still occur in a concerning number of cases. This study aims to evaluate the effect of cement augmentation of the new-generation Trochanteric Femoral Nail Advanced (TFNA) perforated spiral blade on complications including fixation failure in the elderly population.

Materials And Methods: We retrospectively evaluated 107 patients aged 65 + treated for pertrochanteric fractures via TFNA between 2015 and 2019 based on whether cementation was used. Baseline demographics, fracture classifications, and reduction quality were compared. Patients with a follow-up of at least 6 months were analyzed for the primary outcome of fixation failure. All patients, regardless of loss to follow-up within 6 months, were analyzed for other complications including mortality.

Results: Seventy-six patients (47 cemented, 29 non-cemented) had a minimum follow-up of 6 months (mean 13 months). There were no statistically significant differences between the two treatment groups in terms of patient demographics, ASA or AO/OTA fracture classification, reduction quality, or length of follow-up. There was a lower rate of fixation failure in the cement-augmented (CA) group versus the non-cement-augmented (NCA) group (2.1% vs 13.8%; p = 0.047). No cut-out or cut-through was observed in the CA group. Seven patients had adverse intraoperative events, with a significantly higher rate of fixation failure in these patients (40% vs 2.8%; p = 0.00). There were no statistically significant differences in 30-day mortality (6.3% CA vs 4.3% NCA; p = 0.632) or 3-month mortality (9.5% CA vs 12.8% NCA; p = 0.589).

Conclusions: Cementation of TFNA blades may decrease risk of fixation failure, however, the surgeon must be aware of potential complications such as cement leakage into the hip joint and be able to manage them as they arise.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-020-03449-9DOI Listing

Publication Analysis

Top Keywords

fixation failure
20
pertrochanteric fractures
12
follow-up 6 months
12
spiral blade
8
complications including
8
reduction quality
8
6 months analyzed
8
failure patients
8
statistically differences
8
rate fixation
8

Similar Publications

Aims: Tibial fixation in revision total knee arthroplasty (rTKA) can present surgical challenges. It has been suggested that appropriate fixation in at least two of the three anatomical zones (epiphysis, metaphysis, and diaphysis) is essential for implant survival. However, supporting clinical data are lacking.

View Article and Find Full Text PDF

Knee pain in patients often involves varus deformity and unicompartmental osteoarthritis (OA). High tibial valgus osteotomy (HTO) is increasingly recognized as an effective treatment, as it realigns the knee's mechanical axis towards the healthier lateral compartment, delaying degenerative changes in the medial compartment and reducing the need for joint replacement. This case report discusses two patients with bilateral knee arthritis and varus deformity who underwent medial opening-wedge high tibial osteotomy (MOWHTO) using Dr.

View Article and Find Full Text PDF

Functional Outcome of Subtrochanteric Femoral Fractures Fixation by Proximal Femoral Locking Compression Plate.

Mymensingh Med J

January 2025

Dr Md Sonaullah, Assistant Professor, Department of Orthopedics and Traumatology, Mymensingh Medical College (MMC), Mymensingh, Bangladesh; E-mail:

Subtrochanteric femoral fractures are one of the common fractures encountered in today's Orthopaedic practice. This area consists of mostly cortical bone with high stress generation thus heal slowly which leads implant failure. The inherent instability of this fracture and forces of the muscles with comminuted medial calcar is giving the fracture a tendency to varus collapse.

View Article and Find Full Text PDF

A tension system for angular correction of bent intramedullary nails: in vitro analysis.

Eur J Orthop Surg Traumatol

December 2024

Department of Orthopedics and Trauma, Universidade Federal Fluminense (UFF), Niterói, Rio de Janeiro, Brazil.

Purpose: Although several techniques have been described for bent intramedullary nail removal, there is no universally accepted strategy. We hypothesized that a device based on the action principle of a three-point bend fixture could facilitate extraction of bent intramedullary nails; this paper describes its design and experimental testing.

Methods: Five large synthetic left femurs and five steel intramedullary nails were used.

View Article and Find Full Text PDF

Background: Distal radius fractures are prevalent in small and toy-breed dogs, presenting significant treatment challenges due to complications such as delayed union or non-union. These complications are often exacerbated by reduced vascular density at the distal diaphyseal-metaphyseal junction of the radius, which is vital for bone healing, particularly in toy and small breed dogs. Circular external fixation (CEF) is known for its effectiveness in managing acute and chronic fractures and providing temporary stabilization in humans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!