Background: Monitoring healthcare workers' (HCWs) hand hygiene (HH) performance is recommended for improving compliance. Observer biases challenge data validity, thus supplemental approaches such as video observation are needed to complement monitoring.

Methods: We investigate first-person view (FPV) video observation during simulated standardized patient care handling a catheter in a study with 71 HCWs. HH performance was evaluated for (1) all HH opportunities and (2) a subset of opportunities required in an ideal work sequence, hereafter core opportunities. HCWs' acceptance of FPV video observation and usability judgments were assessed.

Results: Compliance level for core HH opportunities (M = 43.5%) was significantly higher than compliance considering all opportunities (M = 30.4%, t(70) = 8.493, P < .001). Reducing HH opportunities to core opportunities would significantly increase compliance levels from the observed average of 30.4% to 44.9% (t(70) = 12.822, P < .001). Overall, both usability ratings and acceptance of the body camera were promising.

Discussion: FPV video observation in simulated standardized patient care provides new instruments to evaluate HH performance beyond mere compliance rates. Our results emphasize the role of optimizing workflow in order to improve HCW's HH compliance.

Conclusions: FPV video observation in a standardized patient care simulation is feasible and offers information for HH interventions that target actual deficiencies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajic.2019.11.032DOI Listing

Publication Analysis

Top Keywords

video observation
24
fpv video
16
standardized patient
12
patient care
12
core opportunities
12
healthcare workers'
8
hand hygiene
8
hygiene performance
8
first-person view
8
observation standardized
8

Similar Publications

In health care, work-related musculoskeletal disorders are largely attributed to patient-handling tasks. Reliable assessments of patient mobility are imperative to mitigate the musculoskeletal burden on healthcare providers. This study explores the reliability of MK5 Mobility Classes, a patient mobility classification system.

View Article and Find Full Text PDF

Objectives: Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is the gold standard for diagnosing gastric subepithelial lesions (SELs), but diagnosing lesions smaller than 20 mm remains challenging. We developed traction-assisted EUS-FNB (TA-EUS-FNB) using the clip-with-thread method to enhance diagnostic accuracy by stabilizing the lesion and providing counter-traction for easier needle access. This study evaluates the effectiveness of TA-EUS-FNB in diagnosing small gastric SELs.

View Article and Find Full Text PDF

BACKGROUND Swallowing is a complex behavior involving the musculoskeletal system and higher-order brain functions. We investigated the effects of different modalities of repetitive transcranial magnetic stimulation (rTMS) on the unaffected hemisphere and observed correlation between suprahyoid muscle activity and cortical activation in unilateral stroke patients when swallowing saliva, based on functional near-infrared spectroscopy (fNIRS). MATERIAL AND METHODS From November 2022 to March 2023, twenty-five patients with unilateral stroke were screened using computed tomography or magnetic resonance imaging and identified via a video fluoroscopic swallow study.

View Article and Find Full Text PDF

Background: With advancements in minimally invasive thoracic surgery techniques, such as video-assisted thoracoscopic surgery and robotic surgery, the design of vascular staplers has evolved to meet the requirements of these procedures. Consequently, newer generations of automatic staplers with improved handling and reduced size have been introduced, such as two-row staplers, which are more maneuverable and less bulky than their three-row counterparts.

Case Presentation: A 68-year-old man with lung cancer underwent a right middle and lower lobectomy due to tumor invasion into the central middle bronchial trunk, rendering the preservation of the middle lobe impossible.

View Article and Find Full Text PDF

Background: This study aims to compare Lung Ultrasound (LUS) findings with High-Resolution Computerized Tomography (HRCT) and Pulmonary Function Tests (PFTs) to detect the severity of lung involvement in patients with Usual Interstitial Pneumonia (UIP) and Non-Specific Interstitial Pneumonia (NSIP).

Methods: A cross-sectional study was conducted on 35 UIP and 30 NSIP patients at a referral hospital. All patients underwent LUS, HRCT, and PFT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!