Objectives: To evaluate the feasibility and image quality of respiratory motion-resolved 4D zero echo time (ZTE) lung MRI compared with that of 3D ZTE.
Methods: Our institutional review board approved this study. Twenty-one patients underwent lung scans using 3D ZTE and 4D ZTE sequences via prospective and retrospective soft gating techniques, respectively. Image qualities of 3D ZTE and 4D ZTE at end-expiration were compared through objective and subjective assessments. The quality of end-expiratory images of 3D ZTE and 4D ZTE of the two groups with different lung functions was also compared.
Results: Images were successfully acquired in all patients without any adverse events. Signal-to-noise ratios (SNRs) of lung parenchyma and thoracic structures were significantly (all p < 0.001) higher in 4D ZTE. Contrast-to-noise ratios (CNRs) of peripheral bronchi, peripheral pulmonary vessels, and nodules or masses were significantly (all p < 0.001) higher in 4D ZTE. The subjective image quality assessed by two independent radiologists showed that intrapulmonary structures, noise and artifacts, and overall acceptability were superior in 4D ZTE (all p < 0.001). Image qualities of groups with normal and low lung functions differed significantly (all p < 0.05) in 3D ZTE, but not in 4D ZTE. The mean acquisition time was 136 s (127-143 s) in 3D ZTE and 325 s (308-352 s) in 4D ZTE.
Conclusions: Respiratory motion-resolved 4D ZTE lung imaging was feasible as part of routine chest MRI. The 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR than the 3D ZTE, regardless of patients' lung function.
Key Points: • ZTE MRI captures rapidly decaying transverse magnetization in the lung parenchyma. • 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR compared with 3D ZTE. • Compared with 3D ZTE, the image quality of 4D ZTE lung MRI was affected less by patients' lung function and respiratory performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-020-06890-x | DOI Listing |
Neuroimage
January 2025
Department of Neuroscience, The Jikei University School of Medicine, Tokyo, Japan; Human Informatics and Interaction Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan; Faculty of Engineering, University of Tsukuba, Tsukuba, Japan. Electronic address:
Functional MRI (fMRI) is an important tool for investigating functional networks. However, the widely used fMRI with T2*-weighted imaging in rodents has the problem of signal lack in the lateral ventral area of forebrain including the amygdala, which is essential for not only emotion but also noxious pain. Here, we scouted the zero-echo time (ZTE) sequence, which is robust to magnetic susceptibility and motion-derived artifacts, to image activation in the whole brain including the amygdala following the noxious stimulation to the hind paw.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
December 2024
From the Department of Radiology (H.N.M., F.B.G.), Bai Jerbai Wadia Hospital for Children, Mumbai, Maharashtra, India.
Background And Purpose: Congenital vertebral anomalies are commonly associated with underlying spinal cord anomaly which necessitates imaging both the spinal cord and the bony vertebral column to understand the extent of the deformity better. While MRI is the gold standard for spinal cord imaging, it does not provide CT-like bone details. Many MR bone imaging techniques have been tested in various adult spine conditions in the past decade but not much has been described on their reliability in pediatric spine.
View Article and Find Full Text PDFPLoS One
December 2024
Beijing Institute of Science and Technology Information, Beijing Academy of Science and Technology, Beijing, China.
In 2018, US government imposed a ban on Chinese electronics firm ZTE, prohibiting it from procuring chip products from American companies for a duration of seven years. Subsequently, ZTE experienced a shutdown. The concept of "bottleneck technology" gained prominence in diverse media outlets.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
Beijing Advanced Innovation Center for Materials Genome Engineering, Institute of Solid State Chemistry, University of Science and Technology Beijing, Beijing 100083, China.
Entropy (Basel)
November 2024
State Key Laboratory of Advanced Rail Autonomous Operation, School of Electronic and Information Engineering, Beijing Jiaotong University, Beijing 100044, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!