Purpose: Detection and accurate localization of renal masses (RM) are important steps toward future potential classification of benign vs malignant RM. A fully automated algorithm for detection and localization of RM may eliminate the observer variability in the clinical workflow.

Method: In this paper, we describe a fully automated methodology for accurate detection and segmentation of RM from contrast-enhanced computed tomography (CECT) images. We first determine the boundaries of the kidneys on the CECT images utilizing a convolutional neural network-based method to be used as a region of interest to search for RM. We then employ a homogenous U-Net-based ensemble learning model to identify and delineate RM. We used an institutional dataset comprised of CECT images in 315 patients to train and evaluate the proposed method. We compared results of our method to those of three-dimensional (3D) U-Net for RM localization and further evaluated our algorithm using the kidney tumor segmentation (KiTS19) challenge dataset.

Results: The developed algorithm reported a Dice similarity coefficient (DSC) of 95.79% ± 5.16% and 96.25 ± 3.37 (mean ± standard deviation) for segmentation accuracy of kidney boundary from 125 and 60 test images from institutional and KiTS19 datasets, respectively. Using our method, RM were detected in 125 and 52 test cases, which corresponds to 100% and 86.67% sensitivity at patient level in institutional and KiTS19 test images. Our ensemble method for RM localization yielded a mean DSC of 88.65% ± 7.31% and 87.91% ± 6.82% on the institutional and KiTS19 test datasets, respectively. The mean DSC for RM delineation from CECT institutional test images using 3D U-Net was 85.95% ± 1.46%.

Conclusion: We describe a method for automated localization of RM using CECT images. Our results are important in terms of clinical perspective as fully automated detection of RM is a fundamental step for further diagnosis of cystic vs solid RM and eventually benign vs malignant solid RM, that has not been reported previously.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.14193DOI Listing

Publication Analysis

Top Keywords

fully automated
16
cect images
16
test images
12
institutional kits19
12
automated detection
8
detection segmentation
8
renal masses
8
computed tomography
8
images
8
benign malignant
8

Similar Publications

Atlantoaxial dislocation (AAD) is a serious condition in which the first two cervical vertebrae lose their anatomical position and stability. This may lead to neurological complications, including death. The treatment of AAD remains controversial, and posterior instrumentation with pedicle screw placement is one of the commonly used methods.

View Article and Find Full Text PDF

Background: To develop and test the performance of a fully automated system for classifying renal tumor subtypes via deep machine learning for automated segmentation and classification.

Materials And Methods: The model was developed using computed tomography (CT) images of pathologically proven renal tumors collected from a prospective cohort at a medical center between March 2016 and December 2020. A total of 561 renal tumors were included: 233 clear cell renal cell carcinomas (RCCs), 82 papillary RCCs, 74 chromophobe RCCs, and 172 angiomyolipomas.

View Article and Find Full Text PDF

An integrated immunofluorescent detection system for automated and sensitive protein quantification based on a microfluidic flow cytometry platform.

Anal Chim Acta

March 2025

Holosensor Medical Technology Ltd, Room 12, No. 1798, Zhonghuayuan West Road, Yushan Town, Suzhou, 215000, China; Department of Veterinary Medicine, University of Cambridge, Cambridge, UK. Electronic address:

Rapid and sensitive protein detection methods are of benefit to clinical diagnosis, pathological mechanism research, and infection prevention. However, routine protein detection technologies, such as enzyme-linked immunosorbent assay and Western blot, suffer from low sensitivity, poor quantification and labourious operation. Herein, we developed a fully automated protein analysis system to conduct fast protein quantification at the single molecular level.

View Article and Find Full Text PDF

Automatic multimodal registration of cone-beam computed tomography and intraoral scans: a systematic review and meta-analysis.

Clin Oral Investig

January 2025

Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, 310006, China.

Objectives: To evaluate recent advances in the automatic multimodal registration of cone-beam computed tomography (CBCT) and intraoral scans (IOS) and their clinical significance in dentistry.

Methods: A comprehensive literature search was conducted in October 2024 across the PubMed, Web of Science, and IEEE Xplore databases, including studies that were published in the past decade. The inclusion criteria were as follows: English-language studies, randomized and nonrandomized controlled trials, cohort studies, case-control studies, cross-sectional studies, and retrospective studies.

View Article and Find Full Text PDF

Background: The asymptomatic onset and extremely high mortality rate of aortic aneurysm (AA) highlight the urgency of early detection and timely intervention. The alteration of retinal vascular features (RVFs) can reflect the systemic vascular properties, and be widely used as the biomarker for cardiovascular disease risk prediction. Therefore, we aimed to investigate associations of RVFs with AA and its progression.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!