This article presents a compact quad flat no-lead (QFN)-packaged second-order bandpass filter (BPF) with intertwined inductors, a dendritic capacitor, and four air-bridge structures, which was fabricated on a gallium arsenide (GaAs) substrate by integrated passive device (IPD) technology. Air-bridge structures were introduced into an approximate octagonal outer metal track to provide a miniaturized chip size of 0.021 × 0.021 λ (0.8 × 0.8 mm) for the BPF. The QFN-packaged GaAs-based bandpass filter was used to protect the device from moisture and achieve good thermal and electrical performances. An equivalent circuit was modeled to analyze the BPF. A description of the manufacturing process is presented to elucidate the physical structure of the IPD-based BPF. Measurements were performed on the proposed single band BPF using a center frequency of 2.21 GHz (return loss of 26.45 dB) and a 3-dB fractional bandwidth (FBW) of 71.94% (insertion loss of 0.38 dB). The transmission zero is located at the 6.38 GHz with a restraint of 30.55 dB. The manufactured IPD-based BPF can play an excellent role in various S-band applications, such as a repeater, satellite communication, and radar, owing to its miniaturized chip size and high performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7215345 | PMC |
http://dx.doi.org/10.3390/ma13081932 | DOI Listing |
Front Pharmacol
December 2024
Department of Anesthesiology, Affiliated Hospital of Zunyi Medical University, Zunyi, China.
Background: Mice play a crucial role in studying the mechanisms of general anesthesia. However, identifying reliable EEG markers for different depths of anesthesia induced by multifarious agents remains a significant challenge. Spindle activity, typically observed during NREM sleep, reflects synchronized thalamocortical activity and is characterized by a frequency range of 7-15 Hz and a duration of 0.
View Article and Find Full Text PDFSci Rep
December 2024
College of Education, Department of Physics, Misan University, Amarah, Iraq.
This study introduces a high-performance 4-channel Metal-Insulator-Metal (MIM) diplexer, employing silver and Teflon, optimized for advanced photonic applications. The proposed diplexer, configured with two novel band-pass filters (BPFs), operates across four distinct wavelength bands (843 nm, 1090 nm, 1452 nm, 1675 nm) by precisely manipulating the passband dimensions. Utilizing Finite-Difference Time-Domain (FDTD) simulations, the designed diplexer achieves exceptional sensitivity values of 3500 nm/RIU, 4250 nm/RIU, 3375 nm/RIU, and 4003 nm/RIU, along with high figures of merit (FOM) ranging from 113.
View Article and Find Full Text PDFJ Neurotrauma
December 2024
Department of Medical Sciences, Section of Neurosurgery, Uppsala University, Uppsala, Sweden.
This study compared the roles of extraparenchymal autonomic nervous system (ANS) control of cerebral blood flow (CBF) versus intraparenchymal cerebrovascular autoregulation in 487 patients with aneurysmal subarachnoid hemorrhage (SAH) and 413 patients with traumatic brain injury (TBI). Vasomotion intensity of extraparenchymal and intraparenchymal vessels were quantified as the amplitude of oscillations of arterial blood pressure (ABP) and intracranial pressure (ICP) in the very low frequency range of 0.02-0.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk, 37673, Republic of Korea.
This study investigates human semicircular canal (SCC) dynamics under off-center rotational conditions. Previous research has modeled human rotational perception and the dynamic response of the SCCs by assuming a centered rotation state, where the rotation axis aligns with the SCC's center. However, this assumption is not representative of most real-life rotational situations.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.
Background: Pulmonary vein isolation (PVI) has been established as an effective management option for symptomatic paroxysmal atrial fibrillation (PAF). We aimed to explore the role of P-wave parameters in a 12-lead electrocardiogram (ECG) in predicting the success of repeat PAF ablation.
Methods: We enrolled consecutive patients who underwent a second AF ablation procedure for PAF in a UK tertiary center after an index ablation conducted between 2018 and 2019 and a repeat ablation up to 2021.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!