Nanomaterials have been increasingly employed for improving the mechanical properties and durability of ultra-high-performance concrete (UHPC) with high volume supplementary cementitious materials (SCMs). Recently, graphene oxide (GO) nanosheets have appeared as one of the most promising nanomaterials for enhancing the properties of cementitious composites. To date, a majority of studies have concentrated on cement pastes and mortars with fewer investigations on normal concrete, ultra-high strength concrete, and ultra-high-performance cement-based composites with a high volume of cement content. The studies of UHPC with high volume SCMs have not yet been widely investigated. This paper presents an experimental investigation into the mini slump flow and physical properties of such a UHPC containing GO nanosheets at additions from 0.00 to 0.05% by weight of cement and a water-cement ratio of 0.16. The study demonstrates that the mini slump flow gradually decreases with increasing GO nanosheet content. The results also confirm that the optimal content of GO nanosheets under standard curing and under steam curing is 0.02% and 0.04%, respectively, and the corresponding compressive and flexural strengths are significantly improved, establishing a fundamental step toward developing a cost-effective and environmentally friendly UHPC for more sustainable infrastructure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7216208PMC
http://dx.doi.org/10.3390/ma13081929DOI Listing

Publication Analysis

Top Keywords

high volume
16
graphene oxide
8
oxide nanosheets
8
physical properties
8
ultra-high-performance concrete
8
volume supplementary
8
supplementary cementitious
8
cementitious materials
8
uhpc high
8
mini slump
8

Similar Publications

Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model.

View Article and Find Full Text PDF

This study investigated the implementation and impact of fifth-generation (5G) wireless millimeter wave (mmW) technology. 5G offers significant advancements over previous generations and supports additional frequency bands, including mmW, to enhance mobile broadband with ultra-reliable, low-latency communications, supporting a high volume of diverse communications. This technology is expected to enable billions of new connections in the Internet of Things (IoT), fostering innovations in various sectors including healthcare, manufacturing, and education.

View Article and Find Full Text PDF

A Bioabsorbable Implant Seeded with Adipose-Derived Stem Cells for Adipose Regeneration.

Tissue Eng Part A

January 2025

Department of Plastic and Reconstructive Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.

Adipose tissue engineering requires effective strategies for regenerating adipose tissue, with adipose-derived stem cells (ASCs) being favored due to their robust self-renewal capacity and multipotent differentiation potential. In this study, the efficacy of poly-L-lactic acid (PLLA) mesh containing collagen sponge (CS), seeded with ASCs to promote adipose tissue formation, was investigated. PLLA-CS implants seeded with GFP-positive ASCs were inserted at high concentration (1 × 10 cells/implant, H-ASC) and low concentration (1 × 10 cells/implant, L-ASC), as were unseeded controls.

View Article and Find Full Text PDF

Background: Several health care networks have fully adopted second-generation supraglottic airway (SGA) i-gel. Real-world evidence of enhanced patient safety after such practice change is lacking. We hypothesized that the implementation of i-gel compared to the previous LMA®-Unique™ would be associated with a lower risk of airway-related safety events.

View Article and Find Full Text PDF

Risk factors for the recurrence of atrial fibrillation after catheter ablation: a meta-analysis.

Egypt Heart J

January 2025

Department of Cardiology, Lianyungang No 1 People's Hospital, No. 6 East Zhenhua Road, Haizhou District, Lianyungang, 222061, Jiangsu, China.

Background: The rate at which atrial fibrillation (AF) patients experience a return of symptoms after catheter ablation is significant, and there are multiple risk factors involved. This research intends to perform a meta-analysis to explore the risk factors connected to the recurrence of AF in patients following catheter ablation.

Methods: The PubMed, Cochrane Library, WOS, Embase, SinoMed, CNKI, Wanfang, and VIP databases were explored for studies from January 1, 2000 to August 10, 2021, and research meeting the established inclusion requirements was chosen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!