Background: Lumen apposing metal stent (LAMS) allows an easy access to peripancreatic fluid collections (PPFCs) and the possibility of performing direct endoscopic necrosectomy (DEN). The aim of our study was to evaluate the safety and efficacy of a new 20-mm LAMS in the management of PPFCs. This novel stent represents the largest diameter LAMS available on the market to date.

Methods: This is an international, multicenter retrospective study involving 20 centers. Consecutive patients who underwent EUS-guided PPFC drainage using a 20-mm LAMS were included. Primary outcomes were technical and clinical success. Secondary outcomes were rate and the severity of adverse events.

Results: A total 105 patients underwent PPFC drainage using the new 20-mm LAMS and 106 LAMS were placed. Technical success was 100% (106/106). 7/105 patients died due to causes not related to the stent. Clinical success was achieved in 92/98 patients (93.9%). Significant adverse events occurred in 8/98 patients (8.16%): 4 cases (4.08%) of bleeding, 3 cases (3.06%) of suprainfection, 1 case of gastric outlet obstruction.

Conclusions: This multicenter study demonstrated acceptable rates of technical and clinical success using a new 20-mm LAMS for PPFC, including walled-off pancreatic necrosis (WOPN). The results of our study suggest that a new 20-mm LAMS is non-inferior in terms of safety, efficacy, and adverse events as compared to smaller diameter LAMS in the management of PPFCs, including pancreatic psuedocysts (PP) and WOPN. Randomized controlled studies will be needed to determine the ideal size of LAMS need to achieve the greatest clinical benefit with the minimized risk exposure for this high-risk patient population.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-020-07567-8DOI Listing

Publication Analysis

Top Keywords

20-mm lams
20
safety efficacy
12
clinical success
12
lams
11
efficacy 20-mm
8
lumen apposing
8
apposing metal
8
metal stent
8
stent lams
8
peripancreatic fluid
8

Similar Publications

EUS-Directed transDuodenal ERCP in Concomitant Gastric Outlet and Biliary Obstruction.

Gastrointest Endosc

December 2024

Virginia Tech Carilion, Division of Gastroenterology, Roanoke, Virginia.

Background And Aims: Patients with concomitant gastric outlet obstruction (GOO) and biliary obstruction often have limited management options, particularly in the setting of severe debility. We detail the use of EUS guided gastro-duodenal placement of lumen apposing metal stent (LAMS) as a conduit for transduodenal ERCP: EUS-Directed transDuodenal ERCP (EDDE).

Methods: Nine patients that developed GOO with indwelling biliary metal stents or with anticipated biliary stent placement were retrospectively included.

View Article and Find Full Text PDF

Mirizzi syndrome is a rare complication of chronic gallstone disease characterised by the compression of the common bile duct due to an impacted lithiasis in the infundibulum of the gallbladder or cystic duct. In this case study, we discuss an 85-yearold patient who presented with Mirizzi syndrome associated with septic shock. She was not eligible for cholecystectomy due to her advanced age and frailty, requiring a less invasive alternative.

View Article and Find Full Text PDF

Endoscopic ultrasound-directed transgastric intervention (EDGI) is a technique that creates an anastomosis between the gastric pouch or jejunum to the excluded stomach in Roux-en-Y gastric bypass (RYGB) anatomy to allow access to the pancreaticobiliary system. Thus far, management of anastomosis closure at the time of lumen-apposing metal stent (LAMS) removal has varied widely. This study aimed to assess the efficacy of primary closure at the time of LAMS removal using a through-the-scope (TTS) tack-based suture system.

View Article and Find Full Text PDF

Background And Aim: Endoscopic ultrasound-directed trans-gastric retrograde cholangiopancreatography (EDGE) is a new procedure for treating pancreaticobiliary diseases in patients with Roux-en-Y gastric bypass (RYGB). The aim of this meta‑analysis was to determine the overall outcomes and safety of EDGE.

Materials And Methods: We performed a computerized search of the main databases, including PubMed, EMBASE, Cochrane Library, and Science Citation Index, through October 2022.

View Article and Find Full Text PDF

Background/aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction.

Methods: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!