A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Control of ventricular unloading using an electrocardiogram-synchronized pulsatile ventricular assist device under high stroke ratios. | LitMetric

Pulsatile ventricular assist devices (pVADs) yield a blood flow that imitates the pulsatile flow of the heart and, therefore, could diminish the adverse events related to the continuous flow provided by the ventricular assist devices that are commonly used. However, their intrinsic characteristics of larger size and higher weight set a burden to their implantation, that along with the frequent mechanical failures and thrombosis events, reduce the usage of pVADs in the clinical environment. In this study, we investigated the possibility to reduce the pump size by using high pump stroke ratios while maintaining the ability to control the hemodynamics of the cardiovascular system (CVS). In vitro and in vivo experiments were conducted with a custom pVAD implemented on a hybrid mock circulation system and in five sheep, respectively. The actuation of the pVAD was synchronized with the heartbeat. Variations of the pump stroke ratio, time delay between the pump stroke and the heart stroke, as well as duration of the pump systole in respect to the total cardiac cycle duration were used to evaluate the effects of various pump settings on the hemodynamics of the CVS. The results suggest that by varying the operating settings of the pVAD, a pulsatile flow that provides physiological hemodynamic parameters, as well as a control over the hemodynamic parameters, can be achieved. Additionally, by employing high pump stroke ratios, the size of the pVAD can be significantly reduced; however, at those high pump stroke ratios, the effect of the other pump parameters diminishes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.13711DOI Listing

Publication Analysis

Top Keywords

pump stroke
20
stroke ratios
16
ventricular assist
12
high pump
12
pump
9
pulsatile ventricular
8
assist devices
8
pulsatile flow
8
hemodynamic parameters
8
stroke
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!