Purpose: To analyze the impact of different veneering techniques on the fracture load of telescopic secondary crowns made of a high-performance polymer (Ultaire aryl ketone polymer [UAKP]).

Materials And Methods: Zirconia primary crown models (taper of 0 degrees) were prepared (N = 48), polished, scanned, and divided into four veneering groups (n = 12 each): premanufactured, digital, full anatomical, and vestibular. For all groups except vestibular, a standardized telescopic secondary crown (thickness: 0.6 mm, circular margin: 1 mm) was constructed, adapted to the corresponding primary crown, milled from UAKP, and veneered. The veneered master crown was developed based on the premanufactured group. After surface polishing, all specimens were artificially aged in a chewing simulator (1.2 million cycles, 50 N, 1.1 Hz, between 5°C and 55°C). Fracture load was tested in a universal testing machine with a piston (Ø = 6 mm, 1 mm/minute). Fracture patterns were analyzed. For statistical analysis, Kolmogorov-Smirnov test and descriptive statistics followed by one-way ANOVA with post hoc Scheffé test were conducted (P < .05).

Results: Significant differences in fracture load were found between different veneering techniques (P < .001), with the highest values for the vestibular and digital groups, followed by the premanufactured group. Full anatomical veneering showed the significantly lowest fracture load (1,885 ± 397 N). For all specimens, cohesive brittle fractures with similar fracture patterns occurred, irrespective of the veneering technique.

Conclusion: The veneering technique of telescopic secondary crowns made of high-performance polymer affects overall stability. All veneering techniques provided sufficient fracture load values for telescopic secondary crowns made of UAKP. Digital veneers seem the most recommendable.

Download full-text PDF

Source
http://dx.doi.org/10.11607/ijp.6669DOI Listing

Publication Analysis

Top Keywords

fracture load
24
telescopic secondary
20
secondary crowns
16
crowns high-performance
12
high-performance polymer
12
veneering techniques
12
fracture
8
zirconia primary
8
veneering
8
impact veneering
8

Similar Publications

Bioabsorbable magnesium-based bulk metallic glass composite (BMGC) for improved medial opening wedge high tibial osteotomy in knee osteoarthritis.

J Orthop Translat

January 2025

Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, 6F Biomedical Technology Building, No. 301, Yuantong Rd., Zhonghe Dist., New Taipei City, 23564, Taiwan.

Background And Objective: Osteoarthritis is a widespread and debilitating condition, particularly affecting the medial compartment of knee joint due to varus knee deformities. Medial opening wedge high tibial osteotomy (MOWHTO) has emerged as an effective treatment, but it comes with challenges like fractures, correction loss, and nonunion, leading to unsatisfactory results in up to 26 % of patients. In response, our study explores the potential of a bioabsorbable magnesium-based bulk metallic glass composite (MgZnCa BMGC) enriched with molybdenum particles as an innovative solution for MOWHTO.

View Article and Find Full Text PDF

The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.

View Article and Find Full Text PDF

Super-strong hydrogel reinforced by an interconnected hollow microfiber network via regulating the water-cellulose-copolymer interplay.

Sci Bull (Beijing)

January 2025

Hubei Biomass-Resource Chemistry and Environmental Biotechnology Key Laboratory, Hubei Provincial Engineering Research Center of Emerging Functional Coating Materials, School of Resource and Environmental Sciences, Wuhan University, Wuhan 430079, China. Electronic address:

The discontinuous fiber reinforced hydrogels are easy to fail due to the fracture of the fiber matrix during load-bearing. Here, we propose a novel strategy based on the synergistic reinforcement of interconnected natural fiber networks at multiple scales to fabricate hydrogels with extraordinary mechanical properties. Specifically, the P(AA-AM)/Cel (P(AA-AM), poly(acrylic acid-acrylamide); Cel, cellulose) hydrogel is synthesized by copolymerizing AA and AM on a substrate of paper with an interconnected hollow cellulose microfiber network.

View Article and Find Full Text PDF

In this work, the fracture mechanism of winding carbon-fiber-reinforced plastics (CFRPs) based on epoxy matrices reinforced by polysulfone film was investigated. Two types of polymer matrices were used: epoxy oligomer (EO) cured by iso-methyltetrahydrophthalic anhydride (iso-MTHPA), and EO-modified polysulfone (PSU) with active diluent furfuryl glycidyl ether (FGE) cured by iso-MTHPA. At the winding stage, the reinforcing film was placed in the middle layer of the CFRP.

View Article and Find Full Text PDF

The key structural components of a wind turbine blade, such as the skin, spar cap, and shear web, are fabricated from fiber-reinforced composite materials. The spar, predominantly manufactured via resin infusion-a process of resin injection and curing in carbon fibers-is prone to initial defects, such as pores, wrinkles, and delamination. This study suggests employing the pultrusion technique for spar production to consistently obtain a uniform cross-section and augment the reliability of both the manufacturing process and the design.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!