Background: Severe bone and soft tissue defects are common after failed two-stage exchange arthroplasty for periprosthetic joint infection (PJI). There is a paucity of evidence on the outcomes of using a hinged prosthesis for knee PJI reconstruction during second-stage re-implantation, especially regarding implant survivorship, reinfection risk factors, and functionality after successful reconstruction.
Methods: A total of 58 knee PJI patients with Anderson Orthopaedic Research Institute (AORI) type II/III defect and soft tissue insufficiency underwent reconstruction with hinged prosthesis. Enrolled patients adhered to a two-stage exchange arthroplasty protocol and were evaluated for a mean follow up of 65.1 months. Kaplan-Meier analysis was conducted for implant survivorship and infection-free survival. Multivariate analysis was used to determine independent risk factors for recurrent infections. Knee Society Score (KSS) was used to evaluate functional outcomes.
Results: The survivorship of hinged prosthesis was 86.2% at 2 years and 70.2% at 5 years. Infection-free analysis revealed an estimation of 68.9% at 2 years and 60.6% at 5 years. Of the 58 patients, 13 (22.4%) developed recurrent PJI, three (5.2%) aseptic loosening, and one (1.7%) periprosthetic fracture. Multivariate analysis revealed that obesity (hazard ratio (HR), 3.11), high-virulent pathogen (HR, 3.44), and polymicrobial infection (HR, 3.59) were independent risk factors for reinfection. Patients showed a mean improvement of 32.8 ± 7.7 in Knee Society Clinical Score (KSCS) and 30.8 ± 11.0 in Knee Society Function Score (KSFS) after successful reconstruction (P<0.001).
Conclusions: Using hinged knee prosthesis for PJI reconstruction provided an overall implant survival of 70.2% and an infection-free survival of 60.6% at mid-term follow up. Obesity, virulent pathogens, and polymicrobial infections were independent risk factors for infection recurrence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.knee.2020.03.004 | DOI Listing |
Total knee arthroplasty (TKA) with hardware around the knee is a challenge to preserve bone while boney landmarks are distorted. Robotic assisted (RA) TKA may assist in simultaneous hardware removal and TKA due to preoperative planning and retention of bone. The aim of this study is to identify if there are differences in component fixation, component constraint and functional outcomes dependent during simultaneous removal of hardware (ROH) around the knee and TKA comparing RA-TKA to manual.
View Article and Find Full Text PDFJt Dis Relat Surg
January 2025
İstanbul Fizik Tedavi ve Rehabilitasyon Eğitim ve Araştırma Hastanesi, Ortopedi ve Travmatoloji Kliniği, 34180 Bahçelievler, İstanbul, Türkiye.
Objectives: This study aims to investigate quantitatively the protective effect of a 1.6-mm or a 2.5-mm Kirschner wire (K-wire) on the medial hinge at different gap distances through finite element analysis (FEA) and to establish whether using a 2.
View Article and Find Full Text PDFArch Orthop Trauma Surg
December 2024
1st Orthopaedics and Traumatology Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
Background: The Coonrad-Morrey prosthesis (CMP) is a widely applied semi-constrained implant that effectively counteracts compression and thrust on the hinge. The aim of this systematic review was to evaluate the indications and outcomes of CMP across different aetiologies for which it was implanted.
Materials And Methods: Selected articles were reviewed to extract: population data, surgical indications, preoperative and postoperative clinical outcomes, survival rate, and complications.
Knee
January 2025
Department of Orthopaedic Surgery, National Medical Center, Seoul, Republic of Korea. Electronic address:
Background: The literature provides limited evidence regarding postoperative outcomes and complications following simultaneous bilateral medial opening-wedge high tibial osteotomy (MOWHTO). This study aimed to investigate the clinical outcomes and complications associated with simultaneous bilateral MOWHTO.
Methods: We retrospectively evaluated 72 knees from 36 patients (mean age, 58.
J Orthop Surg Res
November 2024
Department of Orthopedic Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan-Si, Gyeongki-Do, Republic of Korea.
Background: The study aimed to evaluate whether a new OhtoFix plate reduced stress around the D-hole compared with an old OhtoFix and TomoFix plate. The study also assessed whether the new OhtoFix plate had biomechanical stability in a lateral hinge fracture (LHF).
Methods: A finite element model of the proximal tibia was developed using cross-sectional images from a 62-year-old Asian woman.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!