This study aimed at performing a comparative analysis of the fracture resistance of implants, evaluating extra-narrow, narrow, and regular implants. Four groups containing 15 implants each were evaluated. Group 1 (G1): single-piece extra-narrow implants; Group 2 (G2): single-piece narrow implants; Group 3 (G3): Morse taper narrow implants with solid abutments; Group 4 (G4): Morse taper conventional implants with solid abutments. The implants were tested using a universal testing machine for their maximum force limit and their maximum bending moment. After obtaining the data, the Shapiro-Wilk, ANOVA, and Tukey ( < 0.05) statistical tests were applied. Samples from all the groups were analyzed by scanning electron microscopy and Groups 3 and 4 were analyzed by profilometry. The means and the standard deviation values for the maximum force limit (N) and the maximum bending moment (Nmm) were respectively: G1:134.29 N (10.27); G2:300.61 N (24.26); G3:360.64 N (23.34); G4:419.10 N (18.87); G1:1612.02 Nmm (100.6); G2:2945 Nmm (237.97); G3:3530.38 Nmm (228.75); G4:4096.7 Nmm (182.73). The groups behaved statistically different from each other, showing that the smallest diameter implants provided less fracture resistance, both in the tensile strength tests and in the maximum bending moment between all groups. Furthermore, single-piece implants, with 2.5 mm and 3.0 mm diameters, deformed in the implant body region area, rather than in the abutment region.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7215707PMC
http://dx.doi.org/10.3390/ma13081888DOI Listing

Publication Analysis

Top Keywords

maximum bending
12
bending moment
12
implants
11
comparative analysis
8
extra-narrow narrow
8
fracture resistance
8
group single-piece
8
implants group
8
narrow implants
8
group morse
8

Similar Publications

Background: Lifting is generally considered as a risk factor for low back pain. A thorough investigation of the muscle function during lifting is essential for a better assessment of the potential risk of muscle impairment and towards improvements in lifting strategy. We aimed to compare the activities of the trunk muscles between the stoop and the squat lifting tasks.

View Article and Find Full Text PDF

In urban concentrated area, the disturbance caused by construction affects significantly the sustainability of adjacent existing structures. It is essential to capture the mechanical response of existing structures to adjacent deep excavation. The objective of this paper is to investigate the displacement and internal force behavior of elevated bridge piles (BP) subject to influence of deep excavation.

View Article and Find Full Text PDF

Improvement of Bending Stiffness of Timber Beams with Ultra-High-Modulus-Carbon-Fibre-Reinforced Polymer Sheets.

Materials (Basel)

December 2024

Department of Theory of Structures and Building Information Modeling (BIM), Faculty of Civil Engineering and Architecture, Kielce University of Technology, Al. Tysiaclecia Panstwa Polskiego 7, 25-314 Kielce, Poland.

The bending stiffness of beams represents a pivotal parameter influencing both the dimensions of the elements during their design and their subsequent utilisation. It is evident that excessive deflections can cause discomfort to users and contribute to further structural degradation. The objective of this study was to enhance the bending stiffness of timber beams by bonding a composite sheet to their external surfaces.

View Article and Find Full Text PDF

In recent years, steel-fiber-reinforced concrete (SFRC) has been increasingly applied in shield tunnel engineering. However, most research on SFRC segments focuses on the load-bearing capacity, while the tunnel deformation is an equally critical indicator that decides if the tunnel can operate safely during service conditions. Therefore, it is essential to also study the stiffness variations in SFRC segments, which is closely connected to the serviceability limit state (SLS).

View Article and Find Full Text PDF

The preparation of biological phenolic resin (PF) with green recyclable biomaterials instead of phenol is a research hotspot for solving current resource and environmental problems. In this study, on the basis of introducing lignin into the phenolic system, daidzein of a renewable resource with a rigid structure was selected to modify lignin-based phenolic resin (LPF), and the improvement of the mechanical and thermal properties of the modified phenolic resin under different substitution ratios was studied. The friction materials were prepared with a daidzein-modified lignin-based phenolic resin (D-LPF) as the matrix binder, and their effects on the mechanics and friction and wear properties of friction materials were investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!