A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Precise investigation of digital guide plates applied to implant surgery of anterior teeth]. | LitMetric

[Precise investigation of digital guide plates applied to implant surgery of anterior teeth].

Hua Xi Kou Qiang Yi Xue Za Zhi

Dept. of Oral Implantology, The Affiliated Stomatology Hospital of Southwest Medical University, Luzhou 646000, China;Dept. of Oral and Maxillofacial Surgery, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, China.

Published: April 2020

Objective: To study the precision of digital guide plates applied to the implant surgery of anterior teeth.

Methods: Fifty patients scheduled to receive implant restoration treatment in anterior teeth were enrolled in this study and divided into two groups (n=25, each group): those who were given routine implant restoration treatment (control group, 45 implants) and those who received implant restoration treatment using a digital guide plate (test group, 51 implants). After implantation, planned and placed implants were superimposed using digital software, and deviations (corona, apex, depth, degree) were analyzed. Esthetic parameters were assessed at 1 week (baseline), 6 month, and 1 year post final restoration. Pink esthetic (PES) and white esthetic (WES) scores were respectively used to evaluate the soft tissue and restoration esthetic outcome.

Results: The deviation parameters in the test group were significantly lower than those in the control group (P<0.05). PES and WES values recorded for the control group at 1 week, 6 month, and 1 year post final restoration were significantly lower than those in the test group (P<0.05).

Conclusions: The digital guide plate can improve the accuracy of the three-dimensional position of implants in the maxillary esthetic zone. As such, this device may play an important role in obtaining the ideal aesthetic effects of maxillary anterior teeth.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7184289PMC
http://dx.doi.org/10.7518/hxkq.2020.02.011DOI Listing

Publication Analysis

Top Keywords

digital guide
12
implant restoration
12
restoration treatment
12
guide plates
8
plates applied
8
applied implant
8
implant surgery
8
surgery anterior
8
control group
8
group implants
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!