Pullout force of minimally invasive surgical and open pedicle screws-a biomechanical cadaveric study.

J Spine Surg

Faculty of Medicine and Health Sciences, Department of Biomedical Sciences, Biomechanics Research Group, 2 Technology Place, Macquarie University, NSW, Australia.

Published: March 2020

Background: To assess whether lumbar pedicle screw placement with a minimally invasive surgical (MIS) open technique imparts different biomechanical parameters and thus may affect failure rates.

Methods: Human cadaveric disarticulated lumbar vertebrae 1-5 were stabilised in cement. Pedicle screws were inserted either via the 'MIS' or 'open' technique, based on previously described anatomical landmarks. Each vertebra had one 'MIS' and one 'open' technique screw. Specimens were tested with an Instron mechanical testing machine, positioned to allow for testing of direct coaxial force. Load was applied until failure occurred, and load-displacement curves generated for each screw.

Results: Average failure load was found to be 685±399 N for MIS, versus 661±323 N for open technique (P=0.75). The average ultimate failure load was 748±421 N for MIS, versus 772±326 N for open (P=0.74). Average displacement until failure was 0.95±0.49 mm for MIS as compared to 0.95±0.62 mm for open (P=0.996). Axial stiffness was 936±217 N/mm for MIS and 1,016±263 N/mm for open (P=0.19). Average work required to result in failure was 0.84±1.09 J for MIS and 0.82±1.05 J for open (P=0.94).

Conclusions: There was no significant difference in the biomechanical properties of the MIS as compared with open lumbar pedicle screws, when tested until failure under direct coaxial force. The clinical implication may be that there is no significant advantage in the biomechanical properties of MIS versus open lumbar pedicle screw insertion techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7154348PMC
http://dx.doi.org/10.21037/jss.2020.01.15DOI Listing

Publication Analysis

Top Keywords

lumbar pedicle
12
mis versus
12
open
9
minimally invasive
8
invasive surgical
8
pedicle screw
8
mis
8
open technique
8
pedicle screws
8
'mis' 'open'
8

Similar Publications

[The best preferable sagittal vertical axis for the ankylosis spondylitis with thoracolumbar kyphosis following one-level pedicle subtraction osteotomy under different cervical range of motion].

Zhonghua Yi Xue Za Zhi

January 2025

Division of Spine Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing210008, China.

To analyze the influence of cervical range of motion on the preferable sagittal vertical axis in ankylosis spondylitis (AS)-related thoracolumbar kyphosis following single-level pedicle subtraction osteotomy (PSO). The clinical data of sixty-five AS patients who underwent single-level PSO from February 2012 to November 2018 in the Drum Tower Hospital of Nanjing University Medical School were retrospectively reviewed. Of the patients, 59 were males and 6 were females with a mean age of (34.

View Article and Find Full Text PDF

Objective: In the current study, to demonstrate the advantages of oblique lateral interbody fusion (OLIF), we focused on the therapeutics for lumbar spinal tuberculosis with the comparison of three treatments, including anterior approach, posterior approach, and OLIF combined with posterior percutaneous pedicle screw fixation.

Methods: This study included patients with lumbar spinal tuberculosis from July 2015 to June 2018. We divided these patients into three groups: 35 patients underwent an anterior-only approach (Group A), 36 patients underwent a posterior-only approach (Group B), and 31 patients underwent OLIF combined with posterior percutaneous pedicle screw fixation (Group C).

View Article and Find Full Text PDF

Objective: This study aims to explore the predictive value of endplate morphology and pedicle screw bone quality score on screw loosening after single-level lumbar spinal fusion surgery.

Methods: A retrospective analysis was conducted on the clinical data of 207 patients who underwent single-level lumbar spinal fusion (34 in the screw loosening group and 173 in the non-screw loosening group). Univariate analysis and binary logistic regression model analysis were performed using SPSS 27.

View Article and Find Full Text PDF

Applying a three-dimensional curved lumbar spine model to simulate surgery for training residents in pedicle screw insertion.

Surg Radiol Anat

December 2024

Department of Anatomy, Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Bornova, 35100, Izmir, Turkey.

Purpose: The challenges of spinal surgery can be overcome by deeply understanding the anatomical and surgical complexities of the region through the use of model simulators. This study investigates the impact of digitally designed simulators, specifically lumbar spinal models with abnormal curvature, on preoperative planning and their effectiveness as training tools. The study addresses challenges in spine surgery, such as unique deformities, classification issues, and associated abdominal structure abnormalities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!