Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Blood biomarkers of Alzheimer's disease (AD) have attracted much attention of researchers in recent years. In clinical studies, repeated freeze/thaw cycles often occur and may influence the stability of biomarkers. This study aims to investigate the stability of amyloid-β 1-40 (Aβ), amyloid-β 1-42 (Aβ), and total tau protein (T-tau) in plasma over freeze/thaw cycles.
Methods: Plasma samples from healthy controls ( = 2), AD patients (AD, 3) and Parkinson's disease patients (PD, = 3) were collected by standardized procedure and immediately frozen at -80°C. Samples underwent 5 freeze/thaw (-80°C/room temperature) cycles. The concentrations of Aβ, Aβ, and T-tau were monitored during the freeze/thaw tests using an immunomagnetic reduction (IMR) assay. The relative percentage of concentrations after every freeze/thaw cycle was calculated for each biomarker.
Results: A tendency of decrease in the averaged relative percentages over samples through the freeze and thaw cycles for Aβ (100 to 97.11%), Aβ (100 to 94.99%), and T-tau (100 to 95.65%) was found. However, the decreases were less than 6%. For all three biomarkers, no statistical significance was found between the levels of fresh plasma and those of the plasma experiencing 5 freeze/thaw cycles ( > 0.1).
Conclusions: Plasma Aβ, Aβ, and T-tau are stable through 5 freeze/thaw cycles measured with IMR.