A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single Coil Implantable Cardioverter Defibrillator Leads in Patients With Hypertrophic Cardiomyopathy. | LitMetric

Patients with hypertrophic cardiomyopathy (HC) may require higher energies to terminate ventricular fibrillation (VF); thus, dual coil defibrillation leads are often implanted. However, single coil leads may be preferred in young patients. All patients with HCM implanted with a transvenous ICD from years 2000 to 2014 were included. Of 249 patients, 223 underwent VF testing including 150 with a dual coil lead and 73 a single coil. Patients tested with dual coil compared with single coil had lower successful VF energies (15.7 ± 6.1 joule to 20.2 ± 7.9 joule (p <0.0001)). Adequate safety margin for defibrillation was noted in 97.3% of patients. Notably, 6 (4 with single coil leads) had inadequate safety margins (defined as ≥10 joule). Three of these 6 patients required replacement of a single coil lead with a dual coil lead. The remaining 3 underwent waveform tilt alteration, higher energy ICD, or removal of the can from the shock vector. There were no clinical or implant predictors of inadequate safety margins. In follow-up of 16 ± 30 months (range 0 to 170), there were 24 arrhythmias including 13 VF, all successfully terminated. In conclusion, in HC patients undergoing ICD implantation, single coil leads can provide adequate safety margins. In conclusion, defibrillation testing should be considered in all HC patients undergoing ICD implantation, and should be performed in those undergoing implantation with a single coil lead.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2020.03.011DOI Listing

Publication Analysis

Top Keywords

single coil
16
dual coil
12
patients hypertrophic
8
hypertrophic cardiomyopathy
8
patients
6
coil
6
single
4
coil implantable
4
implantable cardioverter
4
cardioverter defibrillator
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!