Background: Evaluate the fracture resistance of endodontically treated teeth after cervical preflaring and root canal preparation and to assess the volume of the root canal and the amount of remaining root dentin before and after cervical preflaring.

Methods: Forty-four mandibular incisors were selected using micro-CT scanning and distributed into 4 groups (n = 11) according to the instrument used for cervical preflaring: control group - no cervical preflaring; Gates Glidden - burs size #2 and #3; WXN - 25.07 Navigator instrument; and Easy - 25.08 ProDesign S instrument. Coronal opening was performed, and the canals were prepared with Wave One Gold Primary and filled with an epoxy-resin based sealer and gutta-percha cones. Micro-CT scans were performed before and after root canal instrumentation. All images were reconstructed and assessed for the thickness of mesial and distal root dentin at 3 mm and 5 mm from the cement -enamel junction and for the volume of cervical portion of the canal after preparation. Fracture resistance test was performed applying compressive loads at a crosshead speed of 0.5 mm/min, applied on the palatal aspect of specimens at 135° along the long axis of the tooth. The data were analyzed using ANOVA and Tukey's test (P = .05).

Results: Cervical preflaring and canal preparation reduced the dentin thickness (P < .05) and increased the canal volume (P < .05) in all groups at 3 mm an 5 mm. Cervical preflaring with Gates Gliden burs reduced the fracture resistance of endodontically treated teeth (P < .05).

Conclusions: All instruments reduced the dentin thickness and increased the canal volume in the cervical at 3 mm and 5 mm. Gates Glidden reduced fracture resistance of mandibular incisors submitted to cervical preflaring, whereas NiTi instruments did not.

Clinical Relevance: Cervical preflaring assumes particular importance previously to the root canal preparation because it minimizes the occurrence of operative accidents, and permits more accurate determination of working length and the apical diameter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7161170PMC
http://dx.doi.org/10.1186/s12903-020-1050-8DOI Listing

Publication Analysis

Top Keywords

cervical preflaring
20
root canal
16
canal preparation
16
fracture resistance
12
preflaring root
8
preparation fracture
8
resistance endodontically
8
endodontically treated
8
treated teeth
8
root dentin
8

Similar Publications

Background And Objectives: The initial size of a root canal is established by progressively introducing K-files according to the increase in the International Organization for Standardization (ISO) size in the apical region. The initial file-fit sensation is caused by coronal interferences rather than always occurring at the apex, as is commonly believed. Flaring the canal at its earliest stages enables the practitioner to accurately assess the size of the canal approaching the apex.

View Article and Find Full Text PDF

The aim of this study was to evaluate the influence of cervical preflaring on the choice of reciprocating file size (Reciproc system) and the difficulty in reaching the working length for instrumentation of molar root canals. A total of 352 human molars were divided into 2 groups of 176 molars each. In the no preflaring (NPF) group, no cervical preflaring was performed.

View Article and Find Full Text PDF

Evaluation of design, mechanical properties, and torque/force generation of heat-treated NiTi glide path instruments.

BMC Oral Health

November 2022

Department of Conservative Dentistry, Kyung Hee University Medical Center, 23 Kyungheedae-Ro, Dongdaemun-Gu, Seoul, 02447, Republic of Korea.

Background: Recently, various kinds of heat-treated nickel-titanium (NiTi) glide path instruments have been manufactured. This study aimed to investigate design, phase transformation behavior, mechanical properties of TruNatomy Glider (#17/02), V Taper 2H (#14/03), and HyFlex EDM (#15/03) and compare torque/force generated during simulated glide path preparation with them.

Methods: The designs and phase-transformation behaviors of the instruments were examined via scanning electron microscopy (n = 3) and differential scanning calorimetry (n = 2).

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the accuracy of the auto apical function in the maintenance of the apical limit of instrumentation during glide path procedures when associated to OGP kinematics of Tri Auto ZX2, compared to the continuous rotation of the same motor, as well as Root ZX II and VDW Gold.

Materials And Methods: Forty-eight extracted human mandibular single-rooted premolars were selected. After endodontic access, cervical pre-flaring was performed using size 30, 0.

View Article and Find Full Text PDF

Aim: To conduct a systematic review and meta-analysis according to the following PICO question: in extracted human permanent teeth, does preflaring, compared with unflared canals, influence the accuracy of WL determination with EAL?

Material And Methods: A systematic review was conducted according to the PRISMA checklist, using the following databases: PubMed, Science Direct, Scopus, and Web of Science. Studies related to WL determination using EAL both in preflared and unflared root canals of extracted human teeth were included. The outcome of interest was the accuracy of the electronic WL determination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!