A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Practical 3D-Printed Model for Training of Endoscopic and Exoscopic Intracerebral Hematoma Surgery with a Tubular Retractor. | LitMetric

Objective:  To present a three-dimensional (3D)-printed model that simulates endoscopic and exoscopic intracerebral hematoma (ICH) surgery with a tubular retractor.

Methods:  We used 3D printing technology to develop the model that consisted of the skull frame and a replaceable inserted module. Edible gelatin and animal blood were placed into the module to mimic brain tissue and the hematoma. Twenty neurosurgeons were recruited to participate in our training program that required the use of an endoscope and an exoscope to aspirate the hematoma with a tubular retractor. Five postgraduates were asked to complete the entire training with the endoscope five times. Questionnaires were distributed for feedback after the training program.

Results:  The more experienced surgeons obviously performed better than the rather inexperienced surgeons, verifying that our model could reflect the ability of the trainees. As the training progressed, the scores of the postgraduates increased, and the average score of the fifth training was obviously higher than the first score. No significant differences were observed in the trainees' performance with the endoscope and the exoscope. The feedback questionnaires showed the average score for value of the simulator as a training tool was a 3.65 (on a 4-point scale). Our model received better comments regarding the bone texture (mean: 3.20), the brain tissue texture (mean: 3.20), and the experience in aspirating the hematoma (mean: 3.10). The surgical position (mean: 2.95), surgical approach (mean: 2.90), and simulated brain tissue (mean: 2.85) should be improved.

Conclusion:  Our model was practical for endoscopic and exoscopic ICH surgery training. The results of our program showed that prior surgical experience benefited the mastery of both the endoscopic and the exoscopic ICH surgery in the 3D-printed model. Our model could make mastering basic skills more efficient.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0039-1697023DOI Listing

Publication Analysis

Top Keywords

endoscopic exoscopic
16
3d-printed model
12
ich surgery
12
brain tissue
12
model
8
training
8
exoscopic intracerebral
8
intracerebral hematoma
8
surgery tubular
8
tubular retractor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!