Background: Preoperative localization of the perforators allows precise planning of the flap design and improves surgical efficiency. Recently, infrared thermography is introduced as a reliable alternative, where the perforator corresponds to the "hot spot" on the thermogram. This study aims to compare the application of color Doppler ultrasound (CDU) and infrared thermography in preoperative perforator mapping of the anterolateral thigh (ALT) perforator flap.
Patients And Methods: From September 2017 to January 2019, CDU and infrared thermography were both applied on 20 patients to locate the perforators originated from lateral circumflex femoral artery preoperatively. The perforators identified using each modality were marked on the anterolateral thigh region. The accuracy of both mapping methods was analyzed according to the intraoperative findings. The relation between location bias and the thickness of subcutaneous tissue was analyzed.
Results: A total of 20 ALT flaps were included. Fifty-three perforators were detected by CDU, and 51 "hot spots" were identified by infrared thermography, in which 50 "hot spots" corresponded to CDU, and the consistency test showed that the κ index was 0.712 (P < 0.05), representing high consistency. The infrared thermography has a sensitivity of 94.3% and a specificity of 85.7% compared with CDU. The deviation between thermal imaging and CDU was positively correlated with the thickness of the subcutaneous tissue. The Pearson correlation coefficient was 0.84 (R = 0.84). Forty-four perforators marked by CDU were selected for designing the flap. Anatomical findings showed that the accuracy rate of CDU and infrared thermal was 93.2% (41 of 44) and 86.3% (38 of 44), respectively. There was no statistical difference (P > 0.05).
Conclusions: Compared with CDU, infrared thermography can be used to locate perforators, in this case, the ALT perforators, with a high degree of consistency. It is portable, economical, noninvasive, and easy to operate. It has higher accuracy in patients with thinner subcutaneous tissue. We believe that infrared thermography can be a useful technique for perforator mapping, especially in patients where the subcutaneous tissue is thinner.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SAP.0000000000002369 | DOI Listing |
Sensors (Basel)
January 2025
Research and Development Center of Optoelectronic Hybrid IC, Guangdong Greater Bay Area Institute of Integrated Circuit and System, Guangzhou 510535, China.
Short-wave infrared (SWIR) imaging has a wide range of applications in civil and military fields. Over the past two decades, significant efforts have been devoted to developing high-resolution, high-sensitivity, and cost-effective SWIR sensors covering the spectral range from 0.9 μm to 3 μm.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Mechanical & Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
This study presents a novel approach for monitoring waste substrate digestion under high-density polyethylene (HDPE) geomembranes in sewage treatment plants. The method integrates infrared thermal imaging with a clustering algorithm to predict the distribution of various substrates beneath Traditional outdoor large-scale opaque geomembranes, using solar radiation as an excitation source. The technique leverages ambient weather conditions to assess the thermal responses of HDPE covers.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Department of Mechanical and Mechatronic Engineering, National Taiwan Ocean University, Keelung 202301, Taiwan.
The effect of dispersing multiwalled carbon nanotubes (MWCNTs) and graphene nanoplatelets (GNPs) in the matrix on the low-velocity impact resistance and post-impact residual tensile strength of the carbon fiber reinforced epoxy composite laminates has been experimentally analyzed in this study. The composite specimens with the matrix reinforced by different nanoparticle types and various nanoparticle concentrations (0.1, 0.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdansk, Poland.
Composites have found applications in critical components and require a high degree of safety and reliability. To ensure this, structural health monitoring systems based on optical fibres embedded within structures are installed for continuous monitoring. Infrared thermography is a non-destructive method that can be applied to inspect the internal structure after manufacturing and during operation.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain.
The aim of this study was to analyze the association between circulating amino acids and central and peripheral body temperature in subjects with and without fibromyalgia syndrome (FMS). A total of 47 patients with FMS and 59 healthy subjects were included in the study. The concentration of amino acids was determined in serum samples using a fluorimeter coupled with a high-performance liquid chromatography system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!