Objective: The internal target volume (ITV) strategy generates larger planning target volumes (PTVs) in locally advanced non-small cell lung cancer (LA-NSCLC) than the Mid-position (Mid-p) strategy. We investigated the benefit of the Mid-p strategy regarding PTV reduction and dose to the organs at risk (OARs).
Methods: 44 patients with LA-NSCLC were included in a randomized clinical study to compare ITV and Mid-p strategies. GTV were delineated by a physician on maximum intensity projection images and on Mid-p images from four-dimensional CTs. CTVs were obtained by adding 6 mm uniform margin for microscopic extension. CTV to PTV margins were calculated using the van Herk's recipe for setup and delineation errors. For the Mid-p strategy, the mean target motion amplitude was added as a random error. For both strategies, three-dimensional conformal plans delivering 60-66 Gy to PTV were performed. PTVs, dose-volume parameters for OARs (lung, esophagus, heart, spinal cord) were reported and compared.
Results: With the Mid-p strategy, the median of volume reduction was 23.5 cm ( = 0.012) and 8.8 cm ( = 0.0083) for PTV and PTV respectively; the median mean lung dose reduction was 0.51 Gy ( = 0.0057). For 37.1% of the patients, delineation errors led to smaller PTV with the ITV strategy than with the Mid-p strategy.
Conclusion: PTV and mean lung dose were significantly reduced using the Mid-p strategy. Delineation uncertainty can unfavorably impact the advantage.
Advances In Knowledge: To the best of our knowledge, this is the first dosimetric comparison study between ITV and Mid-p strategies for LA-NSCLC.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10993224 | PMC |
http://dx.doi.org/10.1259/bjr.20190692 | DOI Listing |
Radiother Oncol
January 2025
Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, the Netherlands.
J Med Educ Curric Dev
December 2024
Department of Infectious Diseases, Hôtel Dieu de France, Saint Joseph University of Beirut, Beirut, Lebanon.
Objective: In Lebanon, HIV prevalence among key populations such as men who have sex with men is high at 12%, warranting a need for targeted healthcare efforts. Pre-exposure prophylaxis (PrEP) is an effective prevention measure, yet global challenges persist, including limited awareness of PrEP among healthcare professionals. This study investigates PrEP awareness within the Lebanese medical community.
View Article and Find Full Text PDFInvest Radiol
November 2024
From the Department of Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany (R.H., E.K., Z.B., D.P., R.C., A.R., K.D.); Institute of Applied Mathematics, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany (T.P., A.E.); Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA (D.P.); Division of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany (D.P., H.-P.S.); Department of Diagnostic and Interventional Radiology With Nuclear Medicine, Thoraxklinik at University Hospital Heidelberg, Heidelberg, Germany (M.F.-D., K.S., G.H., C.P.H.); Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany (M.F.-D.); Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany (V.W., C.P.H.); Translational Lung Research Center Heidelberg, Member of the German Center of Lung Research (DZL), Heidelberg, Germany (C.P.H.); Praxisnetz, Radiology and Nuclear Medicine, Bonn, Germany (M.V.); Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany (J.A.L.); Chair of Civil Law, Data Protection Law, Law of Data Economy, Digitalization and AI Law, Faculty of Law, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany (L.S.-R.); and German Center for Neurodegenerative Diseases (DZNE), Helmholtz Association of German Research Centers, Venusberg-Campus 1, Bonn, Germany (A.R., K.D.).
Objectives: Small lesions are the limiting factor for reducing gadolinium-based contrast agents in brain magnetic resonance imaging (MRI). The purpose of this study was to compare the sensitivity and precision in metastasis detection on true contrast-enhanced T1-weighted (T1w) images and artificial images synthesized by a deep learning method using low-dose images.
Materials And Methods: In this prospective, multicenter study (5 centers, 12 scanners), 917 participants underwent brain MRI between October 2021 and March 2023 including T1w low-dose (0.
Radiother Oncol
October 2024
Radiotherapy Oncology Department, Léon Bérard Cancer Center, Lyon, France.
Background: Locally advanced non-small cell lung cancer (LA-NSCLC) reported poor 5-year survival rates with frequent local or regional recurrences. Personalized RT may contribute to improve control and clinical outcome. We investigated efficacy and tolerance of "Mid-position" (Mid-P) strategy versus the conventional Internal Target Volume (ITV) strategy in LA-NSCLC patients treated by definitive conformal radiotherapy.
View Article and Find Full Text PDFComput Biol Med
March 2024
Department of Physics and Astronomy, Ghent University, Ghent, Belgium.
Cardiac arrhythmias such as atrial fibrillation (AF) are recognised to be associated with re-entry or rotors. A rotor is a wave of excitation in the cardiac tissue that wraps around its refractory tail, causing faster-than-normal periodic excitation. The detection of rotor centres is of crucial importance in guiding ablation strategies for the treatment of arrhythmia.