In the human femoral neck, the contribution of the cortical and trabecular architecture to mechanical strength is known to depend on the load direction. In this work, we investigate if QCT-derived homogenized voxel finite element (hvFE) simulations of varying hip loading conditions can be used to study the architecture of the femoral neck. The strength of 19 pairs of human femora was measured ex vivo using nonlinear hvFE models derived from high-resolution peripheral QCT scans (voxel size: 30.3 µm). Standing and side-backwards falling loads were modeled. Quasi-static mechanical tests were performed on 20 bones for comparison. Associations of femur strength with volumetric bone mineral density (vBMD) or microstructural parameters of the femoral neck obtained from high-resolution QCT were compared between mechanical tests and simulations and between standing and falling loads. Proximal femur strength predictions by hvFE models were positively associated with the vBMD of the femoral neck (R² > 0.61, p < 0.001), as well as with its cortical thickness (R² > 0.27, p < 0.001), trabecular bone volume fraction (R² = 0.42, p < 0.001) and with the first two principal components of the femoral neck architecture (R² > 0.38, p < 0.001). Associations between femur strength and femoral neck microarchitecture were stronger for one-legged standing than for side-backwards falling. For both loading directions, associations between structural parameters and femur strength from hvFE models were in good agreement with those from mechanical tests. This suggests that hvFE models can reflect the load-direction-specific contribution of the femoral neck microarchitecture to femur strength.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.medengphy.2020.03.005 | DOI Listing |
J Orthop Trauma
December 2024
Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA.
Int J Rheum Dis
January 2025
Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, Hunan, China.
Objective: Serum uric acid (SUA) may play positive roles in diseases associated with oxidative stress, such as osteoporosis (OP). Nevertheless, the specific impact of SUA levels on both bone mineral density (BMD) and the risk of OP remains uncertain. Considering such information crucial for clinicians when making decisions about urate-lowering therapy (ULT), we sought to fill this gap by conducting dose-response meta-analyses.
View Article and Find Full Text PDFClin Nutr ESPEN
December 2024
Hacettepe University, Faculty of Medicine, Department of Neurology, Ankara, Turkey; Hacettepe University Faculty of Medicine, Department of Neurology, Neurology Intensive Care Unit, Stroke Unit, Ankara. Electronic address:
Background: Premorbid sarcopenia, osteoporosis, and obesity are epiphenomena that affect survival and functional outcomes in patients with acute ischemic stroke. The effects of preexisting sarcopenia and/or osteopenia on long-term outcome after ischemic stroke were herein prospectively studied.
Methods: Dual-energy x-ray absorptiometry (DeXA), bio-impedance analysis (BIA) and muscle ultrasonography (US) data were prospectively collected within the first 72 hours in 297 consecutive acute ischemic stroke patients (45.
J Clin Densitom
December 2024
INEFC-Barcelona Research Group on Sport Sciences (GRCE), National Institute of Physical Education of Catalonia (INEFC), University of Barcelona, Barcelona (UB), Spain. Electronic address:
This study aimed to assess the calcaneal bone mineral density (BMD) of elite female trail runners and evaluate its reliability using a novel DXA method. It also examined the relationship between calcaneal BMD and other regions of interest to better understand bone health in this specific population. A cross-sectional study was conducted with 35 elite female trail runners from the Spanish national team.
View Article and Find Full Text PDFRev Cardiovasc Med
December 2024
Department of Cardiology, Erasmus Medical Center, 3015GD Rotterdam, The Netherlands.
Background: Achieving hemostasis of large bore venous access sites can be challenging and time consuming. Closure devices have proven to be superior in achieving hemostasis, reducing time to ambulation and improving patient comfort, compared to manual hemostasis techniques after femoral venous and arterial access. The closure of the jugular vein following large bore access has not been investigated in previous studies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!