Introduction: With the introduction of digital radiography, the feedback between image quality and over-exposure has been partly lost which in some cases has led to a steady increase in dose. Over the years the introduction of exposure index (EI) has been used to resolve this phenomenon referred to as 'dose creep'. Even though EI is often vendor specific it is always a related of the radiation exposure to the detector. Due to the nature of this relationship EI can also be used as a patient dose indicator, however this is not widely investigated in literature.
Methods: A total of 420 dose-area-product (DAP) and EI measurements were taken whilst varying kVp, mAs and body habitus on two different anthropomorphic phantoms (pelvis and chest). Using linear regression, the correlation between EI and DAP were examined. Additionally, two separate region of interest (ROI) placements/per phantom where examined in order to research any effect on EI.
Results: When dividing the data into subsets, a strong correlation between EI and DAP was shown with all R-squared values > 0.987. Comparison between the ROI placements showed a significant difference between EIs for both placements.
Conclusion: This research shows a clear relationship between EI and radiation dose which is dependent on a wide variety of factors such as ROI placement, body habitus. In addition, pathology and manufacturer specific EI's are likely to be of influence as well.
Implications For Practice: The combination of DAP and EI might be used as a patient dose indicator. However, the influencing factors as mentioned in the conclusion should be considered and examined before implementation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.radi.2020.03.012 | DOI Listing |
JCO Glob Oncol
January 2025
Uganda Cancer Institute, Department of Radiotherapy, Kampala, Uganda.
The evolution of radiation therapy in Uganda has been a journey marked by significant milestones and persistent challenges. Since the inception of radiotherapy services in 1988-1989, there has been a concerted effort to enhance cancer treatment services. The early years were characterized by foundational developments, such as the installation of the first teletherapy units, low-dose-rate brachytherapy units, and conventional simulators, and the recognition of radiation oncologists and medical physicist professionals laid the groundwork for radiotherapy treatment modalities.
View Article and Find Full Text PDFNeurosurg Rev
January 2025
Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Zabrze, 41-808, Poland.
Atlantoaxial dislocation (AAD) is a serious condition in which the first two cervical vertebrae lose their anatomical position and stability. This may lead to neurological complications, including death. The treatment of AAD remains controversial, and posterior instrumentation with pedicle screw placement is one of the commonly used methods.
View Article and Find Full Text PDFNeurosurg Rev
January 2025
Department of Neurosurgery, Pamukkale University School of Medicine, Kim Burchiel Gamma Knife Center, Denizli, Türkiye, Turkey.
This study aims to demonstrate the effect of gamma knife radiosurgery (GKRS) on symptoms, hemorrhage rates, and histopathological changes in patients with cavernous malformations (CMs), regardless of whether the symptomatic lesions are hemorrhagic. This single-center retrospective study evaluated symptomatic patients with single CMs treated with GKRS between 2016 and 2023. The patients' demographic data, presenting symptoms, GKRS radiation dose, complications developed during follow-up (hemorrhage, radiotoxicity), the rate of symptom improvement, and histopathological changes of surgically removed CMs were recorded.
View Article and Find Full Text PDFCardiol Young
January 2025
Pediatric Cardiology, Stead Family Children's Hospital, University of Iowa, Iowa City, IA, USA.
Background: Despite patent ductus arteriosus closure in premature infants is a relatively fast procedure, it involves specific steps for equipment exchange and the use of a 4-Fr catheter, which may be large for tiny infants, potentially causing haemodynamic instability or tricuspid valve regurgitation.
Objectives: This study aims to describe the early experience with a new technique designed to simplify transcatheter patent ductus arteriosus closure in premature infants. It enables the closure using the KA micro plug device via a single microcatheter without equipment exchanges and contrast exposure.
ACS Appl Nano Mater
March 2024
Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!