We show that a commonly accepted transparency threshold for a thin foil in a strong circularly polarized normally incident laser pulse needs a refinement. We present an analytical model that correctly accounts for laser absorption. The refined threshold is determined not solely by the laser amplitude, but by other parameters that are equally or even more important. Our predictions are in perfect agreement with particle-in-cell simulations. The refined criterion is crucial for configuring laser plasma experiments in the high-field domain. In addition, an opaque foil steepens the pulse front, which can be important for numerous applications.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevE.101.033204DOI Listing

Publication Analysis

Top Keywords

threshold thin
8
thin foil
8
foil strong
8
strong circularly
8
circularly polarized
8
laser
5
absorption opacity
4
opacity threshold
4
polarized laser
4
laser field
4

Similar Publications

Sulfides as environmental stressors in Paracas Bay, Peru.

Mar Pollut Bull

January 2025

Facultad de Pesquería, Universidad Nacional Agraria La Molina, Av. La Molina S/N, La Molina, Lima 15024, Peru.

Paracas Bay, located in the Humboldt Current system, is a highly variable coastal environment where hypoxia (dissolved oxygen concentrations <2 mg L) has been reported as a persistent feature of bottom conditions. In addition to hypoxia, milky water events have been reported in the bay, most likely associated with the presence of sulfides (i.e.

View Article and Find Full Text PDF

Functionalization of Polymer Surfaces for Organic Photoresist Materials.

ACS Appl Mater Interfaces

January 2025

Tokyo Electron America, Inc., 2400 Grove Blvd., Austin, Texas 78741, United States.

Photoresists are thin film materials designed to transform an optimal image into a mechanical mask. Diverse exposure techniques such as photolithography induce modifications in the exposed areas that result in solubility changes that can then be selectively removed with appropriate agents (developers). Photoresist materials need to keep pace with the increasingly demand for feature size reduction.

View Article and Find Full Text PDF

Global declines in wild mussel populations and production have been linked to the impacts of climate change and pollution. Summer die-offs of mussels (Perna canaliculus), spat retention issues, and a severe decline in mussel spat settlement have been reported in the Marlborough Sounds, an important area for mussel farming in New Zealand. Preliminary evidence suggests that naturally occurring contaminants and changing land use in the surrounding areas, could contribute to the decline of this species.

View Article and Find Full Text PDF

Improved Consistency of Lung Nodule Categorization in CT Scans with Heterogeneous Slice Thickness by Deep Learning-Based 3D Super-Resolution.

Diagnostics (Basel)

December 2024

Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Republic of Korea.

: Accurate volumetric assessment of lung nodules is an essential element of low-dose lung cancer screening programs. Current guidance recommends applying specific thresholds to measured nodule volume to make the following clinical decisions. In reality, however, CT scans often have heterogeneous slice thickness which is known to adversely impact the accuracy of nodule volume assessment.

View Article and Find Full Text PDF

Assessment of bystander coronary artery disease in transcatheter aortic valve replacement (TAVR) patients using noncoronary-dedicated planning computed tomography angiography (CTA): diagnostic accuracy in a retrospective real-world cohort.

Clin Radiol

December 2024

Department of Radiology, Division of General Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036 Graz, Austria; Department of Radiology and Nuclear Medicine, University Hospital Wiener Neustadt, Corvinusring 3-5, 2700 Wiener Neustadt, Austria.

Aim: To assess the diagnostic potential of a noncoronary-dedicated pre-TAVR CT angiography (CTA) conducted as a prospective ECG-gated scan without premedication and standard cardiac reconstructions in evaluating bystander coronary artery disease (CAD) against invasive coronary angiography (ICA) as the gold standard.

Materials And Methods: This retrospective study included 232 patients who underwent both CTA and ICA as part of their pre-TAVR evaluation. Exclusion criteria included prior stent, pacemaker, coronary artery bypass, or valve surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!