Objective: To define sepsis syndromes in high-HIV burden settings in the antiretroviral therapy (ART) era.

Methods: We characterized a prospective cohort of adults presenting to a tertiary emergency department in Harare, Zimbabwe with suspected community-acquired sepsis using blood and urine cultures, urine tuberculosis lipoarabinomannan (TB LAM), and serum cryptococcal antigen (CrAg) testing. The primary outcome was 30-day all-cause mortality.

Results: Of 142 patients enrolled 68% (n=96/142, 95% confidence interval (CI) [60-75%]) were HIV-positive, 41% (n=39/96, 95% CI [31-50%]) of whom were ART-naïve. Among HIV-positive patients, both opportunistic pathogens (TB LAM-positivity, 36%, 95% CI [24-48%]; CrAg-positivity, 15%, 95% CI [7-23%]) and severe non-AIDS infections (S. pneumoniae urine antigen-positivity 12%, 95% CI [4-20%]; bacteraemia 17% (n=16/96, 95% CI [9-24%]), of which 56% (n=9/16, 95% CI [30-80%]) were gram-negative organisms) were common. Klebsiella pneumoniae recovered from blood and urine was uniformly resistant to ceftriaxone, as were most Escherichia coli isolates. Acknowledging the power limitations of our study, we conclude that relative to HIV-negative patients, HIV-positive patients had modestly higher 30-day mortality (adjusted hazard ratio (HR) 1.88, 95% CI [0.78-4.55]; p=0.16, and 3.59, 95% CI [1.27-10.16], p=0.02) among those with and without viral suppression, respectively.

Conclusion: Rapid point-of-care assays provide substantial clinically actionable information in the setting of suspected sepsis, even in areas with high ART coverage. Antimicrobial resistance to first-line antibiotics in high burden settings is a growing threat.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8040698PMC
http://dx.doi.org/10.1016/j.ijid.2020.04.004DOI Listing

Publication Analysis

Top Keywords

95%
9
suspected sepsis
8
high-hiv burden
8
burden settings
8
blood urine
8
hiv-positive patients
8
presentation outcome
4
outcome suspected
4
sepsis
4
sepsis high-hiv
4

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!