We present a miniaturized precalibration-based forward-viewing Lissajous scanning fiber probe for high speed endoscopic optical coherence tomography (OCT). The probe is based on an asymmetric fiber cantilever driven by the piezoelectric bender to realize two-dimensional (2D) Lissajous scanning. The stability and repeatability of the Lissajous scanning trajectory of the probe is tested by a position sensitive detector (PSD)-based position calibration setup. The two orthogonal resonant frequencies of the cantilever are measured to be 167.2 and 121 Hz. A 25 µm focal spot is formed at the working distance of 5 mm by the graded-index (GRIN) lens, and the field of view of the imaging probe is around ${1.5}\;{\rm mm} \times {1.5}\;{\rm mm}$1.5mm×1.5mm. The probe is fully packaged in a hypodermic tube for endoscopic imaging. The total rigid length and outer diameter are 35 mm and 3.5 mm, respectively. The probe is incorporated in a 50 KHz swept source OCT system with the axial resolution of 14 µm, and its imaging performance is validated by the 2D en face and 3D volumetric OCT imaging of the phantom and the biological tissue.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.389364 | DOI Listing |
Ultramicroscopy
January 2025
College of Artificial Intelligence, Nankai University, Tianjin 300350, China; Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen 518040, China. Electronic address:
Atomic force microscope (AFM) is an important nano-scale surface characterization and measurement method. Raster scanning method (RSM), widely used in AFMs, faces limitations on scanning speed and imaging accuracy. In this paper, an isotropic linear scanning method (ILSM) is proposed to improve the AFM imaging performance.
View Article and Find Full Text PDFThe contacting process of hairpin windings is deemed the most important and challenging process in manufacturing electric vehicle motors. This paper proposes a ring-mode laser contacting method for copper hairpin windings based on Lissajous-shaped cyclic scanning with a uniform angular speed. Two key variables, trajectory cycle n and angular multiplier k, which represent the laser energy input and distribution respectively, were investigated via single-factor experiments.
View Article and Find Full Text PDFWe present a novel endoscopy probe using optical coherence tomography (OCT) that combines sparse Lissajous scanning and compressed sensing (CS) for faster data collection. This compact probe is only 4 mm in diameter and achieves a large field of view (FOV) of 2.25 mm and a 10 mm working distance.
View Article and Find Full Text PDFJ Chem Phys
July 2024
Fakultät Physik, Technische Universität Dortmund, D-44221 Dortmund, Germany.
Large-amplitude thermal excursions imposed on deeply supercooled liquids modulate the nonlinear time evolution of their structural rearrangements. The consequent aftereffects are treated within a Wiener-Volterra expansion in laboratory time that allows one to calculate the associated physical-aging and thermal response functions. These responses and the corresponding higher-harmonic susceptibilities are illustrated using calculations based on the Tool-Narayanaswamy-Moynihan (TNM) model.
View Article and Find Full Text PDFStructured light 3D imaging systems commonly employ panel-based projectors or 1-axis MEMS mirrors with beam expander lens to project multi-frame barcodes or dot clouds, addressing challenges posed by objects with multi-scale feature sizes. However, these methods often result in large system volumes due to the required projection multi-lens modules, high hardware costs, or limited light pattern generation capabilities that hindering measurement precision enhancement. This paper introduces an innovative approach to reconfigurable spatial light pattern projection using a single bi-axial MEMS mirror with Lissajous scanning.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!