Incidence of large for gestational age and predictive values of third-trimester ultrasound among pregnant women with false-positive glucose challenge test.

J Obstet Gynaecol

Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.

Published: February 2021

This cohort study aimed to determine the association between false-positive 50-g GCT and incidence of LGA and to evaluate predictive roles of third-trimester ultrasonographic examination. A total of 200 women with false-positive 50-g GCT and 188 women without GDM risks were enrolled. Third-trimester ultrasonographic examinations were offered. Rate of LGA during third trimester and at birth were compared between groups. Factors associated with LGA and diagnostic properties of third-trimester ultrasonography were evaluated. Incidence of LGA by third-trimester ultrasound and at birth were significantly higher in women with false-positive GCT (19.0% vs. 10.6%,  = .03 and 22% vs. 13.8%;  = .04). Factors associated with LGA included multiparity (adjusted OR 2.32,  = .01), excessive weight gain (adjusted OR 2.57,  = .01) and LGA by ultrasound (adjusted OR 9.79,  < .001). Third-trimester ultrasonography had 47.1% sensitivity, 92.1% specificity and LR + and LR- of 5.96 and 0.57 in identifying LGA infants.Impact statement Women with abnormal GCT but normal OGTT (false positive GCT) might have some degree of glucose intolerance so that GDM-related outcomes could develop, including LGA, macrosomia, shoulder dystocia, and caesarean delivery. Roles of ultrasonography in the prediction of LGA and macrosomia has been reported with mixed results. The results showed that the incidence of LGA, by third-trimester ultrasound and at birth, were significantly increased in women with false-positive GCT. Multiparity, excessive weight gain and LGA by third-trimester ultrasound significantly increased the risk of LGA. Third-trimester ultrasonography had 47.1% sensitivity, 92.1% specificity and LR + and LR- of 5.96 and 0.57 in identifying LGA infants. More intensive behavioural and dietary interventions, together with weight gain control and monitoring, may be needed in women with false-positive GCT to minimise the risk of LGA. Third trimester ultrasonographic examination might be helpful to detect and predict LGA at birth and should be included into routine clinical practice. Further studies that are more widely generalisable are needed to elucidate the relationship between false-positive GCT and adverse pregnancy outcomes and to investigate the benefits of ultrasonographic examination in the prediction of LGA and macrosomia.

Download full-text PDF

Source
http://dx.doi.org/10.1080/01443615.2020.1732890DOI Listing

Publication Analysis

Top Keywords

women false-positive
12
third-trimester ultrasound
8
false-positive 50-g
8
50-g gct
8
incidence lga
8
third-trimester ultrasonographic
8
factors associated
8
associated lga
8
lga
6
third-trimester
5

Similar Publications

Background: A significant proportion of false positive recalls of mammography-screened women is due to benign breast cysts and simple fibroadenomas. These lesions appear mammographically as smooth-shaped dense masses and require the recalling of women for a breast ultrasound to obtain complementary imaging information. They can be identified safely by ultrasound with no need for further assessment or treatment.

View Article and Find Full Text PDF

Background: Clinically meaningful cognitive impairment has typically been defined as a single impaired test score, but this approach is prone to false-positive errors. Examining two test scores at a lower threshold (i.e.

View Article and Find Full Text PDF

Background: Breast implants interfere with myocardial perfusion imaging (SPECT) and echocardiographic windows leading to increased false positive results. To validate this concept, we hypothesized that patients with breast implants should have higher positive cardiac testing and coronary angiogram with lower percutaneous coronary intervention (PCI) rates compared to women without a breast implant.

Methods: Using ICD 10 codes for breast implants, abnormal results of cardiac functional study, coronary angiogram, and percutaneous coronary interventions, we evaluated any association between these parameters in adult women with breast implants utilizing the National Inpatient Sample (NIS) database.

View Article and Find Full Text PDF

Prediction of good neurological outcome after return of circulation following paediatric cardiac arrest: a systematic review and meta-analysis.

Resuscitation

December 2024

Department of Critical Care Medicine, Hospital for Sick Children, Department of Paediatrics, University of Toronto, Neurosciences and Mental Health Program, Research Institute Toronto, ON, Canada.

Aim: To evaluate the ability of blood-biomarkers, clinical examination, electrophysiology, or neuroimaging, assessed within 14 days from return of circulation to predict good neurological outcome in children following out- or in-hospital cardiac arrest.

Methods: Medline, EMBASE and Cochrane Trials databases were searched (2010-2023). Sensitivity and false positive rates (FPR) for good neurological outcome (defined as either 'no, mild, moderate disability or minimal change from baseline') in paediatric survivors were calculated for each predictor.

View Article and Find Full Text PDF

Is it possible to monitor fetal movements with a wearable device? A review of novel technologies.

Eur J Obstet Gynecol Reprod Biol

December 2024

Institute of Reproductive Developmental Biology, Department of Metabolism Digestion and Reproduction, Hammersmith Campus, Imperial College London, London, W12 0HS, United Kingdom. Electronic address:

Article Synopsis
  • Stillbirth is often linked to decreased fetal movements, but current methods for tracking these movements lack accuracy and can lead to unnecessary medical interventions.
  • New technologies, including electrocardiography and accelerometry, are being developed to provide more objective and reliable quantification of fetal movements.
  • The review highlights the need for improved fetal movement monitoring solutions that allow pregnant women to maintain their daily activities while ensuring their baby's wellbeing is effectively monitored.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!