Modern ultrathin struts drug eluting stents (DES), due to their constructive characteristics, might be more prone to stent dislodgment than the old thick DES. Our study is aimed to retrospectively analyze and compare the incidence and outcomes of stents dislodgment in thick (TSS) and ultrathin strut stents (USS).We retrospectively analyzed the procedural and medical data of 8,564 consecutive patients (mean age 64.3 ± 11.2 years old, 4442 males) who underwent percutaneous coronary intervention with DES implantation in our Institution between 1st January 2005 to 1st January 2020. Overall, 25,692 (mean of 3.2 stent for patients) have been implanted over the study period (10648 TSS and 15044 and USS, respectively). Stent dislodgment globally occurred in 0.56% of the implanted stents (0.28% vs 0.78%, p <0.001 for TTS and USS, respectively). Coronary artery calcifications, ostial lesion, coronary artery tortuosity, and a lesion length >25 mm were independent predictors of type I and II USS dislodgments. At 12 months follow up, the rate of target lesion failure was higher in the TTS group (30.7 vs 12.7 %, p <0.001). Stent dislodgement is unusual in the modern era but is more frequent using USS than TTS DES.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2020.03.005DOI Listing

Publication Analysis

Top Keywords

drug eluting
12
eluting stents
12
stent dislodgment
8
dislodgment thick
8
1st january
8
stents
6
risk dislodgement
4
dislodgement ultrathin
4
ultrathin drug
4
stents versus
4

Similar Publications

For individuals at high risk of developing breast cancer, interventions to mitigate this risk include surgical removal of their breasts and ovaries or five years treatment with the anti-estrogen tamoxifen or aromatase inhibitors. We hypothesized that a silicone based anti-estrogen-eluting implant placed within the breast would provide the risk reduction benefit of hormonal therapy, but without the adverse effects that limit compliance. To this end, we demonstrate that when placed adjacent to mammary tissue in the 7,12-dimethylbenz[a]anthracene-induced rat breast cancer model a fulvestrant-eluting implant delays breast cancer with minimal systemic exposure.

View Article and Find Full Text PDF

Various technical methodologies are required to accurately detect substances of different chemical and pharmacological properties in biological samples, which are increasing in number and variety daily. Therefore, laboratories where many samples and different factors are analyzed simultaneously need methods with easy sample preparation, short analysis times and low analysis costs. In this study, the objective was to scan substances susceptible to chemical degradation, amenable to analysis without hydrolysis, and exhibiting short-term stability by employing a straightforward, expeditious, and cost-efficient method.

View Article and Find Full Text PDF

Background And Objective: Total glucosides of paeony (TGP) capsules, tripterygium glycoside tablets (TGT), and celecoxib are commonly used drugs in clinical practice for the treatment of Rheumatoid arthritis (RA). An UPLC-MS/MS method for the analysis of celecoxib in beagle dogs was developed, the herb-drug interactions (HDIs) between TGP and TGT with celecoxib were studied based on pharmacokinetics.

Methods: The method of acetonitrile precipitation was applied to process plasma samples.

View Article and Find Full Text PDF

Background: There are limited comparative data on real-world outcomes of patients undergoing percutaneous coronary intervention (PCI) of the left main (LM) and non-LM coronary arteries.

Methods: 873 consecutive patients undergoing LM PCI (n=256) and non-LM PCI (n=617) were enrolled between September 2019-March 2023 in the Excellence in Coronary Artery Disease (XLCAD) Registry. Primary outcome was 1-year incidence of major adverse cardiovascular events (MACE), a composite of all-cause death, non-fatal myocardial infarction, clinically driven repeat revascularization and ischemic stroke.

View Article and Find Full Text PDF

Drug-Coated Balloon-Based Treatment of Left Main True Bifurcation Lesion.

Catheter Cardiovasc Interv

January 2025

Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Gangnam-gu, South Korea.

Background: There is a paucity of data regarding drug-coated balloon (DCB) treatment in the context of left main (LM) true bifurcation lesions.

Aims: The aim of this study was to evaluate the safety and efficacy of DCB-based treatment for unprotected LM true bifurcation lesions.

Methods: A total of 39 patients with LM true bifurcation lesion (Medina: 1,1,1/0,1,1/1,0,1) who were successfully treated with DCB alone or in combination with drug-eluting stent (DES) were retrospectively enrolled into the DCB-based group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!