A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fast off-line FPSE-HPLC-PDA determination of six NSAIDs in saliva samples. | LitMetric

Fast off-line FPSE-HPLC-PDA determination of six NSAIDs in saliva samples.

J Chromatogr B Analyt Technol Biomed Life Sci

University of Chieti-Pescara "G. d'Annunzio", Department of Pharmacy, Via dei Vestini 31, Chieti 66100, Italy. Electronic address:

Published: May 2020

A fast off-line FPSE-HPLC-PDA method has been reported that allows simultaneous clean up and determination of six non-steroidal anti-inflammatory drugs (NSAIDs) in saliva samples from healthy volunteers. Particularly, furprofen, indoprofen, ketoprofen, fenbufen, flurbiprofen, and ibuprofen were chromatographically resolved. Benzyl paraben was chosen as the internal standard (BzPB, IS). These target compounds were successfully extracted from human saliva using fabric phase sorptive extraction (FPSE) and then analysed in the liquid chromatographic system by means of a short analytical column (Symmetry C18, 75 × 4.6 mm, 3.5 µm) using acetonitrile (AcN) and phosphate buffer (PBS, 30 mM; pH = 2.5) as the mobile phases. The method, validated through the calculation of all analytical parameters in accordance of International Guidelines, was applied to real saliva sample analysis collected from informed volunteers. The proposed approach that included the use of sol-gel polytetrahydrofuran (sol-gel PTHF) sorbent immobilized on cellulose support and C stationary phase used in HPLC, showed high potential as a fast tool for future clinical and forensic applications. The herein reported results encourage potential future application of FPSE in the forensic field. Furthermore, the FPSE membrane was tested in dried saliva spot mode (DSS) in order to check its potential use as a sampling device, also for forensic applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2020.122082DOI Listing

Publication Analysis

Top Keywords

fast off-line
8
off-line fpse-hplc-pda
8
nsaids saliva
8
saliva samples
8
forensic applications
8
saliva
5
fpse-hplc-pda determination
4
determination nsaids
4
samples fast
4
fpse-hplc-pda method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!