Introduction And Purpose: The patellofemoral joint has proved to be the most problematic element of modern TKA for postoperative anterior knee pain; the positioning of the femoral component constitutes a critical phase in this issue. The objective of our study was to evaluate the possible role of either anterior positioning or posterior positioning of the femoral shield compared to the reference plane represented by the anterior cortex, on the anterior knee pain after knee arthroplasty.

Methods: Forty-eight patients treated with TKA were followed up approximately 12 months. None of them have been submitted to any patellar treatment. We observed the position of femoral shield with respect to the anterior cortical line of femur dividing patients into three groups: patients with significant notching, patients with no notching (shield corresponding to anterior cortical line) and patients with anterior positioning of shield. We evaluated clinical and functional outcomes with KSS, anterior knee pain with Kujala's score and adverse events such as periprosthetic fractures.

Results: We found a better clinical and functional result for patients with femoral shield positioned in line with anterior cortical cortex with respect to both TKAs with femoral notching and to protruding anterior femoral components; there were no main differences in anterior postoperative score by Kujala's system. We observed a periprosthetic fracture in a patient with an important femoral notching.

Conclusions: We cannot consider our study as an objective conclusion to the argument. We need more RCTs in order to study the proper influence of either notching or protrusion of femoral shield component onto anterior postoperative pain. Anyway positioning of femoral shield in anterior-posterior direction could be an interesting new critical object of study about anterior knee pain after TKA.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-020-02666-7DOI Listing

Publication Analysis

Top Keywords

femoral shield
20
positioning femoral
16
anterior knee
16
knee pain
16
anterior
14
anterior cortical
12
femoral
10
femoral component
8
anterior-posterior direction
8
postoperative anterior
8

Similar Publications

Background: Ankle and hindfoot fusion in the presence of large bony defects represents a challenging problem. The purpose of this study was to evaluate outcomes of patients who underwent ankle-hindfoot fusions with impaction bone grafting (IBG) with morselized femoral head allograft to fill large bony void defects.

Methods: This was a 3-center, retrospective review of a consecutive series of 49 patients undergoing ankle or hindfoot fusions with femoral head IBG for filling large bony defects.

View Article and Find Full Text PDF

Background: Total hip arthroplasty (THA) is a highly successful orthopedic procedure increasingly performed on younger, obese patients due to its ability to improve functional outcomes and quality of life. However, obesity presents challenges related to implant selection and long-term outcomes, particularly with the use of short femoral stems. While short stems offer benefits such as bone preservation and reduced stress shielding, their reliability in obese patients remains underreported.

View Article and Find Full Text PDF

Background: Total hip arthroplasty (THA) has increased along with an increasing demand for improved quality of life. Combined with prolonged life expectancy, the number of revision surgeries is expected to increase. Stress shielding is a significant issue with traditional femoral stems used in THA, making revision surgeries particularly challenging in younger patients.

View Article and Find Full Text PDF

Mid-term Clinical and Radiographic Outcomes of the Actis Total Hip System: A Retrospective Study.

Cureus

January 2025

Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.

Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.

View Article and Find Full Text PDF

The metastable β-Ti21S alloy exhibits a lower elastic modulus than Ti-6Al-4V ELI while maintaining high mechanical strength and ductility. To address stress shielding, this study explores the integration of lattice structures within prosthetics, which is made possible through additive manufacturing. Continuous adhesion between the implant and bone is essential; therefore, auxetic bow-tie structures with a negative Poisson's ratio are proposed for regions under tensile stress, while Triply Periodic Minimal Surface (TPMS) structures with a positive Poisson's ratio are recommended for areas under compressive stress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!