Background: Minimally invasive spine (MIS) fusion surgery requires image guidance and expert manual dexterity for a successful, efficient, and accurate pedicle screw placement. Operating room (OR)-integrated robotic solution can provide precise assistance to potentially minimize complication rates and facilitate difficult MIS procedures.
Methods: A 5-degrees of freedom robot was designed specifically for a hybrid OR with integrated surgical navigation for guiding pedicle screw pilot holes. The system automatically aligns an instrument following the surgical plan using only instrument tracking feedback. Contrary to commercially available robotic systems, no tracking markers on the robotic arm are required. The system was evaluated in a cadaver study.
Results: The mean targeting error (N = 34) was 1.27±0.57 mm and 1.62±0.85°, with 100% of insertions graded as clinically acceptable.
Conclusions: A fully integrated robotic guidance system, including intra-op imaging, planning, and physical guidance with optimized robot design and control, can improve workflow and provide pedicle screw guidance with less than 2 mm targeting error.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/rcs.2108 | DOI Listing |
J Orthop Surg Res
December 2024
Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, 510006, China.
Objective: This study aims to explore the predictive value of endplate morphology and pedicle screw bone quality score on screw loosening after single-level lumbar spinal fusion surgery.
Methods: A retrospective analysis was conducted on the clinical data of 207 patients who underwent single-level lumbar spinal fusion (34 in the screw loosening group and 173 in the non-screw loosening group). Univariate analysis and binary logistic regression model analysis were performed using SPSS 27.
Surg Radiol Anat
December 2024
Department of Anatomy, Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Bornova, 35100, Izmir, Turkey.
Purpose: The challenges of spinal surgery can be overcome by deeply understanding the anatomical and surgical complexities of the region through the use of model simulators. This study investigates the impact of digitally designed simulators, specifically lumbar spinal models with abnormal curvature, on preoperative planning and their effectiveness as training tools. The study addresses challenges in spine surgery, such as unique deformities, classification issues, and associated abdominal structure abnormalities.
View Article and Find Full Text PDFIndian J Orthop
January 2025
Department of Orthopaedic Surgery, Hillel Yaffe M.C., 3100 Hadera, Israel.
Objective: To present the clinical result of spinal fixation system made entirely of Carbon-Fiber-Reinforced (CFR)-Hybrid Polyaryl-Ether-Ether-Ketone (PEEK).
Summary Of Background Data: Fusion surgery has been used to treat chronic low back pain caused by degenerative disk disease (DDD). The traditional pedicle screw system made of titanium, though biocompatible, can lead to complications, such as stress shielding and implant failure.
Cureus
November 2024
Aerospace Engineering, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.
View Article and Find Full Text PDFInt J Spine Surg
December 2024
Spine Team, Division of Orthopedic Surgery and Musculoskeletal Trauma Care, Geneva University Hospitals, Faculty of Medecine, University of Geneva, Geneva, Switzerland
Background: Navigation increases the precision and safety of pedicle screw placement and has been used to place interbody cages for lateral lumbar interbody fusion. Single-position surgery shortens its duration and that of anesthesia. The aim of this study was the feasibility of simultaneous cage and screw placement in a single prone position using intraoperative navigation without the need for additional fluoroscopy and a detailed technical description of this procedure.