Background: The folate receptor alpha (FRα) is an interesting target for imaging and therapy of different cancers. We present the first in-human radiation dosimetry and radiation safety results acquired within a prospective, multicentric trial (NCT03242993) evaluating the F-AzaFol (3'-aza-2'-[F]fluorofolic acid) as the first clinically assessed PET tracer targeting the FRα.
Material And Methods: Six eligible patients presented a histologically confirmed adenocarcinoma of the lung with measurable lesions (≥ 10 mm according to RECIST 1.1). TOF-PET images were acquired at 3, 11, 18, 30, 40, 50, and 60 min after the intravenous injection of 327 MBq (range 299-399 MBq) of F-AzaFol to establish dosimetry. Organ absorbed doses (AD), tumor AD, and patient effective doses (E) were assessed using the OLINDA/EXM v.2.0 software and compared with pre-clinical results.
Results: No serious related adverse events were observed. The highest AD were in the liver, the kidneys, the urinary bladder, and the spleen (51.9, 45.8, 39.1, and 35.4 μGy/MBq, respectively). Estimated patient and gender-averaged E were 18.0 ± 2.6 and 19.7 ± 1.4 μSv/MBq, respectively. E in-human exceeded the value of 14.0 μSv/MBq extrapolated from pre-clinical data. Average tumor AD was 34.8 μGy/MBq (range 13.6-60.5 μGy/MBq).
Conclusions: F-Azafol is a PET agent with favorable dosimetric properties and a reasonable radiation dose burden for patients which merits further evaluation to assess its performance.
Trial Registration: ClinicalTrial.gov, NCT03242993, posted on August 8, 2017.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7142191 | PMC |
http://dx.doi.org/10.1186/s13550-020-00624-2 | DOI Listing |
EJNMMI Phys
January 2025
Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.
Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.
View Article and Find Full Text PDFBMC Cancer
January 2025
Department of Radiation Oncology, First Affiliated Hospital of Kunming Medical University, 295 Xichang Road, Kunming, 650032, P. R. China.
Introduction: The core objective of this study was to precisely locate metastatic lymph nodes, identify potential areas in nasopharyngeal carcinoma patients that may not require radiotherapy, and propose a hypothesis for reduced target volume radiotherapy on the basis of these findings. Ultimately, we reassessed the differences in dosimetry of organs at risk (OARs) between reduced target volume (reduced CTV2) radiotherapy and standard radiotherapy.
Methods And Materials: A total of 209 patients participated in the study.
Radiol Phys Technol
January 2025
Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore, India.
The estimation of peripheral dose (PD) is vital in cancer patients with long life expectancy. Assessment of PD to radiosensitive organs is important to determine the possible risk of late effects. An attempt has been made to assess the peripheral dose using optically stimulated luminescence dosimeter (OSLD) with megavoltage photon beams as a function of field size, depth, energy, and distance from the field edge.
View Article and Find Full Text PDFMolecules
January 2025
Enviro Ecosmart SME, 189 Tecuci Street, 800552 Galati, Romania.
This study evaluates the effectiveness of Total Reflection X-ray Fluorescence for multi-element analysis in mussels, focusing on sensitivity, precision, and detection limits. Additionally, it offers a cross-regional comparison of elemental composition in mussels from aquaculture farms in Italy, Spain, and Chile. TXRF, using suspensions of mussel samples, proved effective in detecting minor and trace elements, with recovery rates over 80% for Fe, Cu, Zn, As, and Sr.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Military Institute of Chemistry and Radiometry, gen A. Chruściela "Montera" 105, 00-910 Warsaw, Poland.
One of the main objectives of the ion mobility spectrometry (IMS) technique is to reduce moisture in detection systems, which causes the formation of ion clusters and ion water and a reduction in formed clusters' activity. Thus, one of the methods limiting moisture in a sampling injection system is to use hydrophobic polymeric membranes. The use of membranes with high permeability relative to the analysed organic compounds is required, including toxic agents in air (TAAs).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!