Background: Left ventricular global longitudinal strain (GLS) is associated with long-term outcomes of patients with severe aortic stenosis. However, its prognostic value in patients with moderate aortic stenosis remains unknown.
Methods: Patients diagnosed with moderate aortic stenosis (1.0< aortic valve area ≤1.5 cm) and left ventricular ejection fraction ≥50% were identified. GLS was assessed by 2-dimensional strain imaging using speckle-tracking method. All-cause mortality was assessed according to the median GLS value.
Results: Two hundred eighty-seven patients were included (median age 76 years; 47% male). Mean aortic valve area was 1.25 cm, left ventricular ejection fraction 62%, and median GLS -15.2%. During a median follow-up of 3.9 years, there were 103 deaths (36%). Mortality was higher in patients with GLS>-15.2% (hazard ratio 2.62 [95% CI 1.69-4.06]) compared with patients with GLS ≤-15.2% even after adjusting for confounders. Mortality rates at 1, 3, 5 years were 21%, 35%, 48%, respectively, in patients with GLS >-15.2%, and 6%, 15%, 19% in those with GLS ≤-15.2%. Even among those with left ventricular ejection fraction ≥60%, GLS discriminated higher-risk patients (=0.0003). During follow-up, 106 (37%) patients underwent aortic valve replacement with median waiting-time of 2.4 years, and their survival was better than patients without aortic valve replacement. Among those patients undergoing aortic valve replacement, prognosis was still worse in patients with GLS >-15.2% (=0.04). Mortality rates at 1, 3, 5 years were 2%, 10%, 20%, respectively, in patients with GLS >-15.2% and 2%, 5%, 6% in those with GLS ≤-15.2%.
Conclusions: Impaired GLS in moderate aortic stenosis patients is associated with higher mortality rates even among those undergoing aortic valve replacement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCIMAGING.119.009958 | DOI Listing |
Clin Appl Thromb Hemost
January 2025
Cardiovascular Research Institute, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.
View Article and Find Full Text PDFCureus
December 2024
Cardiovascular Surgery, Ayase Heart Hospital, Tokyo, JPN.
Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.
View Article and Find Full Text PDFCureus
December 2024
Family Medicine, Louisiana State University Health Sciences Center, Alexandria, USA.
The VACTERL (vertebral defects, anal atresia, cardiac defects, tracheoesophageal fistula, renal anomalies, and limb abnormalities) association represents an enigmatic syndrome requiring further study. This report describes a full-term neonate born to a multiparous woman who was found, upon further examination, to have multiple congenital abnormalities, including a bicuspid aortic valve, patent foramen ovale, tracheoesophageal fistula (TEF), asymmetric crying facies, microphallus, and a single inguinal testis. The discussion explores environmental and genetic factors that may contribute to this association, as well as similar conditions, such as CHARGE (coloboma, heart defects, choanal atresia, growth retardation, genital abnormalities, and ear abnormalities) syndrome.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
The Y-incision aortic annular enlargement (AAE) has been established as a safe and effective technique for upsizing the aortic annulus by 3 to 4 valve sizes. However, concerns have been raised regarding its technical complexity during reoperations, particularly given the extensive enlargement of the aortic annulus and root. We present a case of reoperative aortic valve replacement after previous Y-incision AAE for prosthetic valve endocarditis and aortic root abscess.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Cardiovascular Surgery, Tokyo Women's Medical University, Tokyo, Japan.
In the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) era, implanting a larger-sized valve during the initial aortic valve replacement is important. For smaller aortic annuli, combining aortic annular and left ventricular outflow tract (LVOT) enlargement is essential. The Y-incision procedure helps achieve implantation of a 2-size larger valve.