A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In Vitro Kinematic Analysis of Single Axis Radius Posterior-Substituting Total Knee Arthroplasty. | LitMetric

In Vitro Kinematic Analysis of Single Axis Radius Posterior-Substituting Total Knee Arthroplasty.

J Knee Surg

Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts.

Published: September 2021

This is an experimental study. As current posterior-substituting (PS) total knee arthroplasties have been reported to incompletely restore intrinsic joint biomechanics of the healthy knee, the recently designed single axis radius PS knee system was introduced to increase posterior femoral translation and promote ligament isometry. As there is a paucity of data available regarding its ability to replicate healthy knee biomechanics, this study aimed to assess joint and articular contact kinematics as well as ligament isometry of the contemporary single axis radius PS knee system. Implant kinematics were measured from 11 cadaveric knees using an in vitro robotic testing system. In addition, medial collateral ligament (MCL) and lateral collateral ligament (LCL) forces were quantified under simulated functional loads during knee flexion for the contemporary PS knee system. Posterior femoral translation between the intact knee and the single axis radius PS knee system differed significantly ( < 0.05) at 60, 90, and 120 degrees of flexion. The LCL force at 60 degrees (9.06 ± 2.81 N) was significantly lower ( < 0.05) than those at 30, 90, and 120 degrees of flexion, while MCL forces did not differ significantly throughout the range of tested flexion angles. The results from this study suggest that although the contemporary single axis radius PS knee system has the potential to mimic the intact knee kinematics under muscle loading during flexion extension due to its design features, single axis radius PS knee system did not fully replicate posterior femoral translation and ligament isometry of the healthy knee during knee flexion.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1708039DOI Listing

Publication Analysis

Top Keywords

single axis
16
axis radius
16
knee system
16
radius knee
12
knee
10
posterior-substituting total
8
total knee
8
healthy knee
8
posterior femoral
8
femoral translation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!