A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spherical Aberration Customization to Extend the Depth of Focus With a Clinical Adaptive Optics Visual Simulator. | LitMetric

Purpose: To evaluate the use of the VAO adaptive optics visual simulator (Voptica SL, Murcia, Spain) for customization of spherical aberration to increase depth of focus.

Methods: Through-focus visual acuity with both high- and low-contrast letters from +1.00 to -3.00 diopters (D) was measured in 17 dilated eyes with three different induced amounts of spherical aberration for a 4.5-mm pupil diameter: control (0 µm), -0.15 µm, and -0.30 µm.

Results: The defocus curves followed the same behavior with both values of contrast, but the visual acuity was 0.2 logMAR lower with low contrast. The mean values of high-contrast logMAR visual acuity at far, intermediate (67 cm), and near (40 cm) were -0.10, 0.11, and 0.37 for control, 0.04, 0.00, and 0.15 for -0.15 µm, and 0.23, 0.00, and 0.06 for -0.30 µm conditions. The 95% confidence interval ranged from ±0.14 to ±0.45 logMAR and the middle 50% of the distribution was approximately 0.2 logMAR.

Conclusions: Negative values of spherical aberration extend the depth of focus in different ways depending on each patient. The VAO is a new instrument that allows the visual customization of spherical aberration to enhance depth of focus. [J Refract Surg. 2020;36(4):223-229.].

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20200212-02DOI Listing

Publication Analysis

Top Keywords

spherical aberration
20
depth focus
12
visual acuity
12
extend depth
8
adaptive optics
8
optics visual
8
visual simulator
8
customization spherical
8
-015 µm
8
visual
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!