A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rotator Cuff Repair With Knotless Technique Is Quicker and More Cost-Effective Than Knotted Technique. | LitMetric

Purpose: To determine the cost-effectiveness of knotted (KT) versus knotless (KL) methods for rotator cuff surgical repair and to assess differences in patients' outcomes.

Methods: We retrospectively identified all patients who underwent arthroscopic rotator cuff repair at 1 institution by 1 surgeon over 2 6-month periods of time (KT technique from August 1, 2013, through January 31, 2014; and KL technique from December 1, 2014, through May 31, 2015) to calculate the direct and indirect costs associated with arthroscopic KT or KL suture bridge rotator cuff repair. Patient demographics, number of anchors used, tendons repaired, procedure time, operative time, and clinical results were also evaluated. We used univariate generalized linear models with a Gaussian distribution for assessment scores and total and implant cost data.

Results: We identified 87 patients for inclusion during the 2 time frames (35 KT, 54 KL). After excluding patients for tear size < 4 cm (n = 42), ≤ 3 anchors (n = 5), revision surgery (n = 1), and those in whom additional procedures were performed (n = 2), 37 eligible subjects remained (n = 15, n = 22). Median implant costs were statistically significantly higher in the KL group than in the KT group (M = $2,127, M = $1,520, β = 413.7, 95% CI: 242.8, 584.6, < .01), and more anchors were used in the KL group, with KT requiring a median of 4 anchors (IQR: 4, 5) and KL requiring a median of 5 anchors (IQR: 5, 5,  = .02). Procedure time was cut in half with KL repair (estimated 43.5 minutes) versus KT repair (80 minutes) (β = 0.5, 95% CI: 0.4, 0.6, < .001). Operating room time also was reduced by approximately 40% (79.5 minutes for KL; 121 minutes for KT [β = 0.6, CI: 0.6, 0.7, < .001]). Once operating room costs were considered, median costs were found to be significantly lower in the KL group (M = $3788.40, M = $4262.90, β = -492.1, 95% CI: -840.0, -144.1, < .01). No statistically significant differences were found between groups in mean preoperative, postoperative or postpreoperative differences in the visual analog scale, Simple Shoulder Test, American Shoulder and Elbow Surgeons, or University of California at Los Angeles scores ( > 0.05 for all).

Conclusions: Despite using more anchors and incurring higher implant costs, the KL technique for rotator cuff repair required less surgical procedure time and cost less overall than the KT technique and resulted in equivalent clinical results.

Level Of Evidence: Level IV Economic and Decision Analyses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7120820PMC
http://dx.doi.org/10.1016/j.asmr.2019.09.005DOI Listing

Publication Analysis

Top Keywords

rotator cuff
20
cuff repair
16
procedure time
12
identified patients
8
implant costs
8
group m =
8
requiring median
8
median anchors
8
anchors iqr
8
operating room
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!