A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Synthesis and properties of poly(DEX-GMA/AAc) microgel particle as a hemostatic agent. | LitMetric

Immediate hemorrhage control without secondary injury is pivotal for saving lives. In this study, polymerized glycidyl methacrylate derivative dextran/acrylic acid (poly(DEX-GMA/AAc)) microgel particles were prepared via emulsion polymerization method as a hemostatic agent. Microgel particles with size distribution of 500-800 nm were chosen because they showed more appropriate characteristics of swelling ratio and gelation time. The results revealed that the microgel particles had excellent swelling ratio of 68.95 g g (w/w), which was 8.4 times that of counterpart clinically used microporous polysaccharide hemospheres, Arista. And poly(DEX-GMA/AAc) showed very short gelation time of 10-13 s. As a result, a gelled film could be formed rapidly after poly(DEX-GMA/AAc) absorbed water in blood when used on wounds, and then staunched bleeding. Poly(DEX-GMA/AAc) microgel particles showed better clotting ability than commercial hemostatic agent Flashclot in vitro. In addition, poly(DEX-GMA/AAc) did not cause exothermic burn when absorbing liquid, which was superior to Flashclot. No obvious toxicity was found in cytotoxicity study and skin irritancy test. Blood loss and hemostasis time were dramatically reduced by poly(DEX-GMA/AAc) microgel particles in hemorrhage models of ear vein, ear artery, liver and femoral artery in rabbits. These results indicated that the poly(DEX-GMA/AAc) microgel particles are a potential hemostatic agent with almost no cytotoxicity and good biocompatibility.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c7tb00768jDOI Listing

Publication Analysis

Top Keywords

microgel particles
24
polydex-gma/aac microgel
20
hemostatic agent
16
polydex-gma/aac
8
swelling ratio
8
gelation time
8
microgel
7
particles
6
synthesis properties
4
properties polydex-gma/aac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!