Rapamycin-loaded nanoporous α-FeO as an endothelial favorable and thromboresistant coating for biodegradable drug-eluting Fe stent applications.

J Mater Chem B

Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China.

Published: February 2017

Iron and its alloys can be potentially employed to fabricate advanced degradable cardiovascular stents due to their excellent mechanical and biocompatibility properties. However, their clinical applications are hindered by their inherent slow degradation rate, the formation of thrombosis and in-stent restenosis. In this study, vertically oriented and orderly arranged α-FeO (hematite) nanotubes with diameters ranging from 30 nm to 70 nm were successfully fabricated on iron substrates using an anodic oxidation approach. These nanotubular coatings acted as drug depots by being loaded with anti-proliferation drug rapamycin to accelerate the re-endothelialization process and being coated by PLGA through a simple spin-coating process to control the drug release rate. The static immersion test showed that the 50 nm-FeO nanotube arrays displayed a faster corrosion rate than pristine Fe, and the PLGA coating effectively reduced the initial burst release of the loaded drug and extended the rapamycin release time to 30 days. The CCK-8 assay and immunofluorescence staining analysis results indicated that the endothelial cells (ECs) on the coated samples showed higher cell viability than the vascular smooth muscle cells (VSMCs), with possible outcomes to promote re-endothelialization and decrease VSMC proliferation. In addition, the surface modified iron exhibited very good hemocompatibility. The current findings suggested that fabricating rapamycin-loaded and PLGA coated FeO nanotubes on a pure iron surface may be a promising method to improve the corrosion rate and accelerate the re-endothelialization of the iron for biodegradable cardiovascular stent applications.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c6tb02634fDOI Listing

Publication Analysis

Top Keywords

stent applications
8
accelerate re-endothelialization
8
corrosion rate
8
iron
5
rapamycin-loaded nanoporous
4
nanoporous α-feo
4
α-feo endothelial
4
endothelial favorable
4
favorable thromboresistant
4
thromboresistant coating
4

Similar Publications

Background: The stent-assisted coiling (SAC) and flow-diverter stent (FDS) techniques are widely used in the endovascular treatment of paraclinoid aneurysms. This article compares the occlusion rate, periprocedural complications, and clinical outcomes of SAC and FDSs.

Methods: Between January 2010 and December 2020, a systematic search of electronic databases identified 2283 articles for screening.

View Article and Find Full Text PDF

Objective: In recent years, the application of robotic assistance in diagnostic and therapeutic endovascular neurointerventional procedures has gained notable attention. In this systematic review and meta-analysis, we aim to evaluate the feasibility, safety, and current indications of robotic-assisted neurointerventions and to assess the degree of robotic assistance and reasons for unplanned manual conversion from robotic assistance.

Methods: We searched Medline, Scopus, Web of Science, and Cochrane Library databases following PRISMA guidelines and included studies with ≥ 4 patients reporting on robotic-assisted neurointerventions.

View Article and Find Full Text PDF

The Purpose: Evaluation of the short-term and long-term results of a phased correction of the tetralogy of Fallot (ToF) with stenting of the right ventricular outflow tract (RVOT) in comparison with a one-stage total correction (TC) of the defect.

Materials And Methods: Two groups of patients with classical ToF were formed. Group 1 (n = 25; median age = 72 days) was initially represented by children with ToF with a more severe clinical status (median weight = 3.

View Article and Find Full Text PDF

Objective: Limitations are sometimes encountered in the application of laparoscopic cholecystectomy to the treatment of acute cholecystitis. Endoscopic gallbladder stenting (EGBS) has emerged as an additional option. However, the long-term stent patency remains an issue.

View Article and Find Full Text PDF

Digital orthodontics has been integrated into NasoAlveolar Molding (NAM) therapy to overcome challenges in the conventional NAM method. This study introduced an individualized Digital NAM (iDNAM) and evaluated the changes in the alveolar ridges and nasolabial morphology after iDNAM treatment. Prospective data were collected from 15 infants with complete unilateral cleft lip and palate who underwent iDNAM therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!