A versatile Johansson-type tender x-ray emission spectrometer.

Rev Sci Instrum

SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA.

Published: March 2020

We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6-5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (∼0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (∼30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5121853DOI Listing

Publication Analysis

Top Keywords

tender x-ray
8
energy resolution
8
versatile johansson-type
4
johansson-type tender
4
x-ray
4
x-ray emission
4
spectrometer
4
emission spectrometer
4
spectrometer high
4
high energy
4

Similar Publications

Meckel's diverticulum (MD) is a common congenital anomaly of the gastrointestinal tract, present in approximately 2% of the population. While typically asymptomatic, MD can lead to complications such as obstruction and intussusception. Here, we present a case report of a man presenting with abdominal pain with an incidental finding of MD complicated by intussusception and our management approach.

View Article and Find Full Text PDF

A male infant presented with reduced oral intake, low-grade fever and postauricular erythema. Clinical examination revealed a soft, tender swelling posteroinferior to the mastoid tip with a dull tympanic membrane on otoscopy. Cross-sectional imaging did not show any evidence of middle ear infection or mastoiditis.

View Article and Find Full Text PDF

Deep venous thrombosis (DVT) has insidious clinical symptoms, and only a few patients suffer from lower limb swelling, tenderness and dorsal flexion pain. We aimed to explore the ultrasonographic features and risk factors of postoperative lower limb DVT in patients with lower limb fractures. Ninety patients with lower limb fractures admitted from January 1st, 2021 to June 30th, 2023 were selected.

View Article and Find Full Text PDF

Objective: To evaluate the NEXUS Chest CT ALL decision instrument (DI) in reducing unnecessary chest CT imaging in minor blunt trauma patients while preserving high sensitivity for detecting clinically meaningful injuries. Additionally, we examined the impact of delayed presentation, chronic disease, and anticoagulation/anti-aggregation medications on trauma outcomes.

Methods: This retrospective study included 853 adult minor blunt trauma patients who underwent chest CT in the emergency department (ED) of Tel-Aviv Sourasky Medical Center between 2018 and 2022.

View Article and Find Full Text PDF

Objective: Disorders of arousal (DoA) are characterized by an intermediate state between wakefulness and deep sleep, leading to incomplete awakenings from NREM sleep. Multimodal studies have shown subtle neurophysiologic alterations even during wakefulness in DoA. The aim of this study was to explore the brain functional connectivity in DoA and the metabolic profile of the anterior and posterior cingulate cortex, given its pivotal role in cognitive and emotional processing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!