Background/purpose: Blade implants account for one of the most debated dental implants design in scientific literature. They have been reconsidered by clinicians since their re-classification by Food and Drug Administration in 2014.
Materials And Methods: The present study aimed to evaluate the outcome of newly manufactured extension implants in the treatment of moderate atrophic posterior maxillae. All the patients enrolled in the present retrospective case series study showed a moderate bone atrophy in the posterior maxilla with a maximum residual height ranging between 4 mm and 8 mm. Implants were inserted with the aid of an electro-magnetic device, and then they covered with screws and left healing. Three months after, implants were exposed and loaded.
Results: Difference between the marginal bone level at the 3-month evaluation (5.57 ± 0.67 mm) and that at baseline (5.67 ± 0.55 mm) appeared to be not significant (p-value = 0.63). At the 12-month evaluation, the marginal bone level (4.95 ± 0.45 mm) underwent significant decrease respect to baseline value as proven by significant change at marginal bone level (-0.62 ± 0.51 mm with a p-value = 0.01).
Conclusion: The results of the present study suggested a positive 12-month outcome for extension implants in the rehabilitation of the moderate atrophic maxilla, without the need of extensive reconstructive surgeries and grafting procedures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7109493 | PMC |
http://dx.doi.org/10.1016/j.jds.2018.11.009 | DOI Listing |
JSES Int
November 2024
Division of Hand and Upper-Extremity Surgery, Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger MSKI, Danville, PA, USA.
Background: Revision total elbow arthroplasty (rTEA) remains a technically challenging procedure with potential for substantial morbidity. Cases involving excessively long cement mantles, removal of well-fixed implants or infected revisions requiring complete cement removal introduce additional technical challenges. Our purpose was to describe the outcomes, results, and complications associated with the use of cortical windows in rTEA.
View Article and Find Full Text PDFHandchir Mikrochir Plast Chir
January 2025
Hand Surgery, Baltalimani Special Hospital for Bone Diseases, Istanbul, Turkey.
Purpose: This study aims to compare the clinical and radiological outcomes of three different techniques used in the surgical treatment of ulnar styloid fractures.
Material And Method: Ulnar styloid fractures treated surgically between 2012 and 2022 were evaluated retrospectively. There were three groups in the study: Group I (Kirschner wire, N= 19), Group II (tension band, N= 27) and Group III (headless compression screw, N= 25).
Biomaterials
January 2025
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA. Electronic address:
Direct pacing of the mid myocardium where re-entry originates can be used to prevent ventricular arrhythmias and circumvent the need for painful defibrillation or cardiac ablation. However, there are no pacing electrodes small enough to navigate the coronary veins that cross these culprit scar regions. To address this need, we have developed an injectable ionically conductive hydrogel electrode that can fill the epicardial coronary veins and transform them into flexible electrodes.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopaedic Surgery and Trauma University Center of Montpellier, University of Montpellier Montpellier France.
Purpose: Gap-balanced total knee arthroplasty (TKA) technique relies on initial ligament evaluation, particularly in patient-specific implantation using computer-assisted technologies. This cadaveric study aimed to compare the reproducibility and reliability of medial and lateral gap measurements between manual stress testing and dynamic ligament balancer.
Methods: Initial gap acquisitions were assessed from eight cadaveric knees (four specimens) during the same navigated TKA procedure by five differently skilled surgeons (three seniors and two juniors).
SICOT J
January 2025
Department of Orthopaedic Surgery, Joint Replacement Unit, Kuala Lumpur Hospital, Ministry of Health Malaysia, Jalan Pahang, 50586 Kuala Lumpur, Malaysia.
Introduction: Extraarticular deformity (EAD) with knee arthritis is a complex condition involving tri-planar bone deformity with pathological malalignment and chronic soft tissue contracture or laxity in the knee joint. Intraarticular correction by TKA, which was previously performed with conventional manual jig by mechanical alignment technique, had its limits and difficulties especially extensive soft tissue release and risk of jeopardizing the collateral ligaments. Robotic technology allows for reproducible and precise execution of surgical plan and allows adjustment to various new personalised alignment philosophy including functional alignment (FA).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!